Analysis of phospholipase A2 glycosylation patterns from venom of individual bees by capillary electrophoresis/electrospray ionization mass spectrometry using an ion trap mass spectrometer.
نویسندگان
چکیده
A method based on tryptic digestion, ultrafiltration and capillary electrophoresis/mass spectrometry (CE/MS) has been developed for the analysis of the glycosylation pattern in the phospholipase A2 (PLA) of individual honeybees. Without reducing the disulfide bonds, PLA was digested with trypsin and filtered with a 3 kDa molecular weight (MW) cut-off membrane. With this procedure, the glycopeptides could be isolated from the nonglycosylated peptides. After tryptic digestion and ultrafiltration, the disulfide bonds were reduced before analysis by CE. To reduce the adsorption, CE separation was performed on successive multiple ionic-polymer (SMIL) polybrene (PB) coated capillary columns. The SMIL-PB columns allowed partial separation of the glycopeptides and eight glycopeptides were identified by on-line coupling of CE with electrospray ionization (ESI) mass spectrometry. The analysis of phospholipase A2 from the venom of individual bees indicated that the variation and relative abundances of different glycopeptides were similar between the younger and the older bees.
منابع مشابه
Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)
The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...
متن کاملOn-line capillary electrophoresis/microelectrospray ionization-tandem mass spectrometry using an ion trap storage/time-of-flight mass spectrometer with SWIFT technology.
The development of a system capable of the speed required for on-line capillary electrophoresis-tandem mass spectrometry (CE-MS/MS) of tryptic digests is described. The ion trap storage/reflectron time-of-flight (IT/reTOF) mass spectrometer is used as a nonscanning detector for rapid CE separation, where the peptides are ionized on-line using electrospray ionization (ESI). The ESI produced ions...
متن کاملIdentification of proteins from two-dimensional gel electrophoresis of human erythroleukemia cells using capillary high performance liquid chromatography/electrospray-ion trap-reflectron time-of-flight mass spectrometry with two-dimensional topographic map analysis of in-gel tryptic digest products.
Protein spots from two-dimensional (2-D) gel electrophoresis of a human erythroleukemia cell line have been identified by analysis of the in-gel tryptic digests using capillary high performance liquid chromatography (HPLC) separation with on-line detection using electrospray ionization mass spectrometry (ESI-MS). This is performed using an electrospray/ion trap storage/reflectron time-of-flight...
متن کاملThe Use of On-line Capillary Electrophoresis/Electrospray Ionization with Detection via an Ion Trap Storage/Reflection Time-of-flight Mass Spectrometer for Rapid Mutation-site Analysis of Hemoglobin Variants
Capillary electrophoresis/electrospray ionization using an ion trap storage/reflectron time-of-flight mass spectrometer detector (CE/ESI-IT/reTOF) is used to provide a rapid and sensitive method for analyzing structural variants in the hemoglobin (Hb) â-chain. The Hb αand â-chains are separated and the â-chain is digested by trypsin. The digest is analyzed by CE/ESI-IT/reTOF where a comparison ...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Rapid communications in mass spectrometry : RCM
دوره 14 21 شماره
صفحات -
تاریخ انتشار 2000