Compressed sensing for chemical shift-based water-fat separation.
نویسندگان
چکیده
Multi echo chemical shift-based water-fat separation methods allow for uniform fat suppression in the presence of main field inhomogeneities. However, these methods require additional scan time for chemical shift encoding. This work presents a method for water-fat separation from undersampled data (CS-WF), which combines compressed sensing and chemical shift-based water-fat separation. Undersampling was applied in the k-space and in the chemical shift encoding dimension to reduce the total scanning time. The method can reconstruct high quality water and fat images in 2D and 3D applications from undersampled data. As an extension, multipeak fat spectral models were incorporated into the CS-WF reconstruction to improve the water-fat separation quality. In 3D MRI, reduction factors of above three can be achieved, thus fully compensating the additional time needed in three-echo water-fat imaging. The method is demonstrated on knee and abdominal in vivo data.
منابع مشابه
CS-Dixon: Compressed Sensing for Water-Fat Dixon Reconstruction
Introduction: Water-fat separation is of interest in several MRI applications including fat suppression and fat quantification. Chemical shift imaging allows robust water-fat separation [1, 2], however the acquisition of multiple images results in prolonged scan time. Accelerated water-fat separation using compressed sensing (CS) was partly addressed in [3] by considering the separation as a sp...
متن کاملCompressive Chemical-Shift-Based Rapid Fat/Water Imaging
Introduction: Chemical-shift based fat and water separation techniques [1,2] are very common in practice and are effective in revealing important clinical information. They require imaging at multiple echo times, which often results in additional scan time. As compressed sensing (CS) [3-5] acceleration techniques become more available, it is necessary to be able to separate between fat and wate...
متن کاملFree-breathing volumetric fat/water separation by combining radial sampling, compressed sensing, and parallel imaging.
PURPOSE Conventional fat/water separation techniques require that patients hold breath during abdominal acquisitions, which often fails and limits the achievable spatial resolution and anatomic coverage. This work presents a novel approach for free-breathing volumetric fat/water separation. METHODS Multiecho data are acquired using a motion-robust radial stack-of-stars three-dimensional GRE s...
متن کاملEfficient T2*- Contrast Manipulations in 3D Abdominal Imaging using Autocorrected Forward/Reverse Spiral MRI
Introduction Besides large volume coverage and short total scan times, image contrast is very important in abdominal MRI. Fat suppression is often required and different T2* weightings are desired for different contrasts in gradient echo acquisitions. Very short and very long TEs facilitate the relevant contrasts of interest for the detection of dedicated contrast media, hemorrhage, iron deposi...
متن کاملQuantification of susceptibility-induced fat resonance shift on chemical shift-based water/fat separation of skeletal muscle
Introduction: The quantification of skeletal muscle fatty infiltration is important in assessing risk factors for metabolic abnormalities (like obesity and diabetes) [1] and in monitoring the progression of myopathies [2]. Muscular fat includes intramyocellular lipids (IMCLs) that are approximated as spherical droplets within myocytes and extramyocellular lipids (EMCLs) that are approximated as...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 64 6 شماره
صفحات -
تاریخ انتشار 2010