Two-dimensional micromechanical bimorph arrays for detection of thermal radiation
نویسندگان
چکیده
Related Articles Comment on “The long range voice coil atomic force microscope” [Rev. Sci. Instrum. 83, 023705 (2012)] Rev. Sci. Instrum. 83, 097103 (2012) Femtosecond pump/supercontinuum-probe setup with 20 kHz repetition rate Rev. Sci. Instrum. 83, 093105 (2012) Velocity map photoelectron-photoion coincidence imaging on a single detector Rev. Sci. Instrum. 83, 093103 (2012) Crosstalk in x-ray framing cameras: Effect on voltage, gain, and timing (invited) Rev. Sci. Instrum. 83, 10E135 (2012) Differential phase contrast x-ray microimaging with scanning-imaging x-ray microscope optics Rev. Sci. Instrum. 83, 083701 (2012)
منابع مشابه
Three-dimensional elasticity solution for vibrational analysis of thick continuously graded sandwich plates with different boundary conditions using a two-parameter micromechanical model for agglomeration
An equivalent continuum model based on the Eshelby-Mori-Tanaka approach was employed to estimate the effective constitutive law for an elastic isotropic medium (i.e., the matrix) with oriented straight carbon nanotubes (CNTs). The two-dimensional generalized differential quadrature method was an efficient and accurate numerical tool for discretizing equations of motion and for implementing vari...
متن کاملInfluence of Thermal Radiation Models on Prediction of Reactive Swirling Methane/Air Flame in a Model Gas Turbine Combustor
A numerical simulation of reactive swirling methane/air non-premixed flame in a new three-dimensional model combustion chamber is carried out to assess the performance of two thermal radiation models, namely, the Discrete Transfer Radiation Model and the P-1 Model. A Finite Volume staggered grid approach is employed to solve the governing equations.The second-order upwind scheme is applied for...
متن کاملA study of the design and the radiation patterns of rectangular bimorph acoustic transducers with thin piezoelectric ceramic plates
In this article, the design of asymmetric bimorph piezoelectric ceramic transducer with loose and fixed edges and with parallel electric excitation is studied. Rectangular piezoelectric ceramic transducers in flexural vibration with straight and parallel nodal lines of vibration are studied. The transducer’s radiation in a plane perpendicular to the surface of the transducer and parallel to the...
متن کاملDesign and the radiation patterns of rectangular symmetric bimorph piezoelectric transducers in cosinusoidal flexural vibration
In this article, the design of rectangular symmetric bimorph piezoelectric ceramic transducers with loose and fixed edges and with parallel electric excitation is studied. Rectangular piezoelectric ceramic transducers in cosinusoidal flexural vibration with straight and parallel nodal lines of vibration are studied. The radiation of the transducer in a plane perpendicular to the surface of the ...
متن کاملTwo-dimensional in situ metrology of X-ray mirrors using the speckle scanning technique
In situ metrology overcomes many of the limitations of existing metrology techniques and is capable of exceeding the performance of present-day optics. A novel technique for precisely characterizing an X-ray bimorph mirror and deducing its two-dimensional (2D) slope error map is presented. This technique has also been used to perform fast optimization of a bimorph mirror using the derived 2D pi...
متن کامل