Ceramic liner fractures presenting as squeaking after primary total hip arthroplasty.

نویسندگان

  • Matthew P Abdel
  • Thomas J Heyse
  • Marcella E Elpers
  • David J Mayman
  • Edwin P Su
  • Paul M Pellicci
  • Timothy M Wright
  • Douglas E Padgett
چکیده

BACKGROUND Squeaking after ceramic-on-ceramic total hip arthroplasty is a relatively uncommon phenomenon. It usually does not require treatment in the absence of pain, mechanical symptoms, and/or relentless squeaking. The purpose of this investigation was to report on four patients who presented with hip pain and squeaking due to fractured ceramic liners after ceramic-on-ceramic total hip arthroplasty. METHODS Four patients with painful squeaking after ceramic-on-ceramic total hip arthroplasty were seen at our institution. One patient had a revision for suspected loosening and excessive anteversion of the cup noted on radiographs and magnetic resonance imaging (MRI). The remaining three patients had a revision for audible squeaking with progressive pain. RESULTS Intraoperatively, the ceramic liners of all four patients were fractured. CONCLUSIONS Squeaking after ceramic-on-ceramic total hip arthroplasty rarely is a functional issue. However, painful squeaking without notable trauma may indicate fracture of the ceramic liner. Painful squeaking is difficult to evaluate by conventional imaging. When painful squeaking occurs, exploration via surgical revision is recommended in selected patients, as ceramic liner fractures may go unnoticed on radiographs and/or MRI and thus their actual prevalence may be higher than estimated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The squeaking hip: a cause for concern-disagrees.

Total hip arthroplasty with ceramic-on-ceramic bearing surfaces has demonstrated low wear with excellent clinical outcomes. More recently, concerns have surfaced because of the presence of audible squeaking in some ceramic-on-ceramic THA patients. The incidence of this phenomenon has been low and has infrequently required reoperation. The exact etiology of squeaking remains unclear but is likel...

متن کامل

Meta-analysis of the Incidence and Risk Factors for Squeaking after Primary Ceramic-on-ceramic Total Hip Arthroplasty in Asian Patients

PURPOSE The purpose of this study was to assess the squeaking incidence and risk factors after primary ceramic-on-ceramic total hip arthroplasty (THA) in Asian patients using meta-analysis. MATERIALS AND METHODS We performed a meta-analysis of published data on the squeaking incidence and risk factors from 2000 to 2013. Eight studies in Asians were analyzed for both squeaking incidence and ri...

متن کامل

Severe metallosis leading to femoral head perforation.

This article describes a case of severe metallosis in a 67-year-old woman who initially underwent primary total hip arthroplasty with a ceramic-on-ceramic articular bearing. This was subsequently revised to a metal-on-polyethylene articulation due to ceramic liner fracture. She presented with severe hip pain and a pelvic mass. Infective workup was negative. Perforation of the cobalt-chrome femo...

متن کامل

A review of squeaking in ceramic total hip prostheses

The occurrence of audible squeaking in some patients with ceramic-on-ceramic (CoC) hip prostheses is a cause for concern. Great effort has been dedicated to understand the mechanics of the hip squeaking to gain a deeper insight into factors contributing to sound emission from CoC hip articulation. Disruption of fluid-film lubrication and friction were reported as the main potential cause, while...

متن کامل

In Vitro and in Vivo Analysis of Squeaking Frequencies in Ceramic-on-ceramic Total Hip Prosthesis

INTRODUCTION: Squeaking after total hip replacement has been reported in up to 10% of patients (1). Some authors proposed that sound emissions from squeaking hips result from resonance of one or other or both of the metal parts and not the bearing surfaces (2). There is no reported in vitro study about the squeaking frequencies under lubricated regime. The goal of the study was to reproduce the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. American volume

دوره 96 1  شماره 

صفحات  -

تاریخ انتشار 2014