Durability of Interior Renderings in Schools: Optimization of Envelope Insulation for Mitigation of Mould Growth Risk
نویسندگان
چکیده
A high standard education is, nowadays, a clear objective for any modern society. In Portugal, the retrofit of educational buildings has an enormous relevance as demonstrated by the ‘‘Program for Retrofit and Upgrade of High Schools’’. Educational buildings specific characteristics such as high occupancy rates and high amount of time children spend in classrooms make them a special case compared to other buildings. Mould growth on envelope surfaces is frequently observed in these buildings, reducing the expected durability of renderings and coatings. The present work consisted of two main lines of research: one of simulation and other of optimization. The simulation part included modelling of Interior Surfaces Temperature, Indoor Air Temperature and Relative Humidity variation, before and after a hypothetical retrofit process. Optimization techniques were applied in the definition of insulation thickness to be numerically tested in the ‘‘after retrofit’’ scenario. The objective was to minimise insulation thickness in each building element of the envelope. The constraints were derived from the control of surface temperature values that would result in mould growth risk.
منابع مشابه
An Optimization Model for Financial Resource Allocation Towards Seismic Risk Reduction
This paper presents a study on determining the degree of effectiveness of earthquake risk mitigation measures and how to prioritize such efforts in developing countries. In this paper a model is proposed for optimizing funds allocation towards risk reduction measures (building retrofitting) and reconstruction process after potential earthquakes in a regional level. The proposed model seeks opti...
متن کاملAssessment of health risk attributed to heavy metals of settled dust in the elementary schools of Bandar Abbas
Background and Objective: Heavy metal (HM) pollution of settled dust on the interior surfaces of elementary schools may affect the health of young students; hence, the health risk of such pollution should be assessed. Therefore, the aims of this study were to measure the content of heavy metals in the settled dust in the indoor of elementary schools in Bandar Abbas and to assess the attributed ...
متن کاملBuilding Retrofit using Vacuum Insulation Panels Hygrothermal Performance and Durability Thesis for the Degree of Doctor of Philosophy
Many old buildings have unsatisfactory thermal performance compared to the standards of today. One way to increase the thermal performance is to add thermal insulation to the building envelope. However, many old buildings are listed and considered to be valuable for historical and esthetic reasons. This often limits the position and thickness of the additional insulation layer. Vacuum insulatio...
متن کاملHygric Performance of a Sandstone Wall Retrofitted with Interior Thermal Insulation
Temperature, relative humidity and overhygroscopic moisture fields in a sandstone wall provided with interior thermal insulation were calculated in order to assess the hygric performance of the retrofitted wall. Computational simulations showed that during the time period of 10 years which was subject of investigation no overhygroscopic moisture appeared in the analyzed building envelope so tha...
متن کاملTrim and Maneuverability Analysis Using a New Constrained PSO Approach of a UAV
Performance characteristic of an Unmanned Air Vehicle (UAV) is investigated using a newly developed heuristic approach. Almost all flight phases of any air vehicle can be categorized into trim and maneuvering flights. In this paper, a new envelope called trim-ability envelope, is introduced and sketched within the conventional flight envelope for a small UAV. Optimal maneuverability of the inte...
متن کامل