Ventricular pacing – Electromechanical consequences and valvular function
نویسندگان
چکیده
Although great strides have been made in the areas of ventricular pacing, it is still appreciated that dyssynchrony can be malignant, and that appropriately placed pacing leads may ameliorate mechanical dyssynchrony. However, the unknowns at present include: 1. The mechanisms by which ventricular pacing itself can induce dyssynchrony; 2. Whether or not various pacing locations can decrease the deleterious effects caused by ventricular pacing; 3. The impact of novel methods of pacing, such as atrioventricular septal, lead-less, and far-field surface stimulation; 4. The utility of ECG and echocardiography in predicting response to therapy and/or development of dyssynchrony in the setting of cardiac resynchronization therapy (CRT) lead placement; 5. The impact of ventricular pacing-induced dyssynchrony on valvular function, and how lead position correlates to potential improvement. This review examines the existing literature to put these issues into context, to provide a basis for understanding how electrical, mechanical, and functional aspects of the heart can be distorted with ventricular pacing. We highlight the central role of the mitral valve and its function as it relates to pacing strategies, especially in the setting of CRT. We also provide future directions for improved pacing modalities via alternative pacing sites and speculate over mechanisms on how lead position may affect the critical function of the mitral valve and thus overall efficacy of CRT.
منابع مشابه
Left atrial booster function in valvular heart disease.
This study was designed to assess atrial booster pump action in valvular heart disease and to dissect booster pump from reservoir-conduit functions. In five patients with aortic stenosis and six with mitral stenosis, sequential atrioventricular (A-V) pacing was instituted during the course of diagnostic cardiac catheterization. Continuous recording of valvular gradient allowed estimation of flo...
متن کاملComparative Electromechanical and Hemodynamic Effects of Left Ventricular and Biventricular Pacing in Dyssynchronous Heart Failure
Comparative Electromechanical and Hemodynamic Effects of Left Ventricular and Biventricular Pacing in Dyssynchronous Heart Failure Electrical Resynchronization Versus Left–Right Ventricular Interaction Joost Lumens, PHD,*y Sylvain Ploux, MD,*y Marc Strik, MD,y John Gorcsan III, MD,z Hubert Cochet, MD,* Nicolas Derval, MD,* Maria Strom, PHD,x Charu Ramanathan, PHD,x Philippe Ritter, MD,* Michel ...
متن کاملValidation of electromechanical wave imaging in a canine model during pacing and sinus rhythm.
BACKGROUND Accurate determination of regional areas of arrhythmic triggers is of key interest to diagnose arrhythmias and optimize their treatment. Electromechanical wave imaging (EWI) is an ultrasound technique that can image the transient deformation in the myocardium after electrical activation and therefore has the potential to detect and characterize location of triggers of arrhythmias. ...
متن کاملVentricular pump function and pacing: physiological and clinical integration.
Optimal cardiac pump function depends on ordered mechanical events that are orchestrated by electrical timing. This electromechanical coupling occurs at multiple anatomic levels: within atria, between atria and ventricles, between ventricles, and especially within the left ventricle (LV). Such disruptions to proper electrical timing result in disordered mechanical events (desynchronization, or ...
متن کاملHemodynamic Consequences of Pacing-Induced Changes
Atrial pacing was performed in 10 patients with various degrees of aortic valvular stenosis (AVS) and the hemodynamics were compared to eight normal subjects. Similar maximum heart rates (135 + 6/min) in each group resulted in no significant complications or symptoms and no changes in cardiac output or transvalvular pressure difference while stroke work (SW) and volume and left ventricular end-...
متن کامل