Thromboelastometry (ROTEM) in children: age-related reference ranges and correlations with standard coagulation tests.

نویسندگان

  • E Oswald
  • B Stalzer
  • E Heitz
  • M Weiss
  • M Schmugge
  • A Strasak
  • P Innerhofer
  • T Haas
چکیده

BACKGROUND The small sample volume needed and the prompt availability of results make viscoelastic methods like rotational thromboelastometry (ROTEM) attractive for monitoring coagulation in small children. However, data on reference ranges for ROTEM parameters in children are scarce. METHODS Four hundred and seven children (ASA I and II) undergoing elective surgery were recruited for this prospective, two-centre, observational study. Subjects were grouped as follows: 0-3, 4-12, 13-24 months, 2-5, 6-10, and 11-16 yr. Study objectives were to establish age-dependent reference ranges for ROTEM assays, analyse age dependence of parameters, and compare ROTEM data with standard coagulation tests. RESULTS Data from 359 subjects remained for final analysis. Except for extrinsically activated clot strength and lysis, parameters for ROTEM assays were significantly different among all age groups. The most striking finding was that subjects aged 0-3 months exhibited accelerated initiation (ExTEM coagulation time: median 48 s, Q1-Q3 38-65 s; P=0.001) and propagation of coagulation (α angle: median 78(o), Q1-Q3 69-84(o); P<0.001) and maximum clot firmness (median 62 mm, Q1-Q3 54-74 mm), although standard plasma coagulation test results were prolonged (prothrombin time: median 13.2 s, Q1-Q3 12.6-13.6 s; activated partial thromboplastin time: median 42 s, Q1-Q3 40-46 s). Lysis indices of <85% were observed in nearly one-third of all children without increased bleeding tendency. Platelet count and fibrinogen levels correlated significantly with clot strength, and fibrinogen levels correlated with fibrin polymerization. CONCLUSIONS Reference ranges for ROTEM assays were determined for all paediatric age groups. These values will be helpful when monitoring paediatric patients and in studies of perioperative coagulation in children.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of thromboelastometry (ROTEM®) with standard plasmatic coagulation testing in paediatric surgery.

BACKGROUND Thromboelastometry (ROTEM(®)) might be useful to detect intraoperative coagulation disorders early in major paediatric surgery. This observational trial compares this technique to standard coagulation tests. METHODS Intraoperative blood sampling was obtained in children undergoing elective major surgery. At each time point, standard coagulation tests [activated partial thromboplast...

متن کامل

Reference Intervals of Thromboelastometric Evaluation of Coagulation in Pediatric Patients with Congenital Heart Diseases: A Retrospective Investigation

BACKGROUND Rotational thromboelastometry (ROTEM®) is a point-of-care test for coagulation, enabling physicians to make a swift decision. The aim of this investigation was to establish reference intervals of thromboelastometric evaluation for coagulation in pediatric patients with congenital heart diseases (CHD). MATERIAL AND METHODS As baseline data, 3 assays of ROTEM® (INTEM, EXTEM, and FIBTEM...

متن کامل

Uncovering Hypercoagulability in Sepsis Using ROTEM

This case series presents three patients with sepsis/septic shock in whom standard coagulation tests (international normalized ratio, activated partial thromboplastin time, fibrinogen, antithrombin, thrombocytes) and ROTEM ® thromboelastometry (InTEM, ExTEM, FibTEM) were simultaneously performed. Although all patients showed significantly prolonged plasmatic coagulation times with a putatively ...

متن کامل

Coagulopathies in Cyanotic Cardiac Patients: An Analysis with Three Point-of-care Testing Devices (Thromboelastography, Rotational Thromboelastometry, and Sonoclot Analyzer)

INTRODUCTION In the last few years, viscoelastic point-of-care (POC) coagulation devices such as thromboelastography (TEG), rotational thromboelastometry (ROTEM), and Sonoclot (SON) analyzer have been increasingly used in major surgeries for timely assessment and management of coagulopathies. The aim of the present study was to evaluate coagulation profile of cyanotic cardiac patients with TEG,...

متن کامل

Effect of thromboelastography (TEG®) and rotational thromboelastometry (ROTEM®) on diagnosis of coagulopathy, transfusion guidance and mortality in trauma: descriptive systematic review

INTRODUCTION The understanding of coagulopathies in trauma has increased interest in thromboelastography (TEG®) and thromboelastometry (ROTEM®), which promptly evaluate the entire clotting process and may guide blood product therapy. Our objective was to review the evidence for their role in diagnosing early coagulopathies, guiding blood transfusion, and reducing mortality in injured patients. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 105 6  شماره 

صفحات  -

تاریخ انتشار 2010