Design and Fabrication of Piezoelectric Micromachined Ultrasound Transducer (pMUT) with Partially-Etched ZnO Film
نویسندگان
چکیده
A square piezoelectric composite diaphragm was analyzed by the finite element method to enhance the sensitivity of a piezoelectric micromachined ultrasound transducer (pMUT). The structures of electrode and piezoelectric film were optimized and a centric electrode was designed to avoid the counteraction of stress in the centre and edges. In order to further improve the sensitivity; a pMUT with partially-etched piezoelectric film was adopted. The receive and transmit sensitivities of the pMUT were analyzed in details. The receive sensitivity of pMUT with partially-etched ZnO film is 3.3 dB or 6.8 dB higher than those with a centric and whole electrode, respectively; and the amplitude of a partially-etched ZnO film pMUT under a certain voltage is 5.5 dB and 30 dB higher than those with centric and whole electrode separately. Two pMUT-based ZnO films were fabricated by micromachining technology and their receive and transmit sensitivities were tested. The ZnO films deposited by direct current (DC) magnetron sputtering exhibit a densely packed structure with columnar crystallites. The test results show that the structure of the square diaphragm with partially-etched piezoelectric layer can significantly improve the transducer sensitivity. The receive sensitivity and transmit sensitivity are -238.35 dB (ref. 1 V/μPa) and 150.42 dB (ref. 1 μPa/V); respectively.
منابع مشابه
Piezoelectric Micromachined Ultrasound Transducer (PMUT) Arrays for Integrated Sensing, Actuation and Imaging
Many applications of ultrasound for sensing, actuation and imaging require miniaturized and low power transducers and transducer arrays integrated with electronic systems. Piezoelectric micromachined ultrasound transducers (PMUTs), diaphragm-like thin film flexural transducers typically formed on silicon substrates, are a potential solution for integrated transducer arrays. This paper presents ...
متن کاملAn Ultra-High Element Density pMUT Array with Low Crosstalk for 3-D Medical Imaging
A ~1 MHz piezoelectric micromachined ultrasonic transducer (pMUT) array with ultra-high element density and low crosstalk is proposed for the first time. This novel pMUT array is based on a nano-layer spin-coating lead zirconium titanium film technique and can be fabricated with high element density using a relatively simple process. Accordingly, key fabrication processes such as thick piezoele...
متن کاملDevelopment of piezoelectric micromachined ultrasonic transducers
Piezoelectric micromachined ultrasonic transducers (pMUTs) are an example of the application of MEMS technology to ultrasound generation and detection, which is expected to offer many advantages over conventional transducers. In this work, we investigate pMUTs through novel design and fabrication methods. A finite element (FE) model, with original tools to measure device performance, was develo...
متن کاملDesign and Fabrication of Piezoelectric Acoustic Sensor
This paper describes a fully integrated acoustic sensor that combines high sensitivity, wide frequency range and low cost of batch processed miniaturized silicon components. A sputtered piezoelectric ZnO layer transforms the mechanical deflection of a thin-etched-Si diaphragm into a piezoelectric charge. ZnO has transparent and conductive properties, which makes it attractive for a variety of s...
متن کاملHigh Frequency and High Fill Factor Piezoelectric Micromachined Ultrasonic Transducers Based on Cavity Soi Wafers
This paper presents a high frequency and high fill factor piezoelectric micromachined ultrasonic transducer (PMUT) array, which is fabricated with a simple and CMOS compatible process based on commercially available cavity SOI wafers. This 2-mask process eliminates the need for through-wafer etching and enables 10× higher fill factor and thereby higher acoustic performance. PMUTs based on both ...