Scientific Requirements for Thermal Control and Scheduling of the STIS MAMA detectors after SM-3
نویسنده
چکیده
The installation of the Aft Shroud Cooling System (ASCS) on the next HST servicing mission will increase the scientific productivity of STIS by reducing the dark current in the MAMA detectors. The “dark glow” now observed in the FUV-MAMA detector is expected to go away at the ~24 ο C nominal operating temperature after SM3. For the NUV-MAMA, typical dark currents will range from 800 to 1100 cts/s. However, for periods of roughly 10 days at a time, the dark current can be reduced to 200-450 cts/s. This is accomplished by warming the NUV-MAMA to ~38 ο C for about 15 days, then cooling rapidly to as low an operating temperature as possible (20 o C is assumed here). This ISR presents an analysis of the NUV-MAMA dark current behavior during the HDF-S campaign, where a similar “cooling campaign” was attempted. It then makes predictions for the NUV-MAMA performance after SM3 and presents recommendations for the number and duration of cooling campaigns. Finally, some preliminary technical requirements for such campaigns are set out.
منابع مشابه
Thermal Motion of the Stis Optical Bench
Various tests have been done of the STIS using internal wavecals to measure thermal motion of the spectral format on the detectors. In most cases, the spectral format moves less than the speci cation not to exceed 0.2 pixels per hour. Primary causes of the motion are 1) changes to the thermal design dictated by the warmer Aft Shroud environment and 2) on-orbit power cycling of MAMA electronics ...
متن کاملUse of FP-SPLIT Slits for Reaching High Signal-to-Noise with MAMA Detectors
A pre-flight uncertainty for STIS was the extent to which the MAMA detectors would support high signal-to-noise observations given inherently low count rates, limitations on available flat fields, and the possibility of evolution in pixel-to-pixel response stability. This ISR reports on results from STIS/SMOV-7091 Pixel-to-pixel Response Stability in which spectra were acquired at high count le...
متن کاملThe Vela Pulsar in the Ultraviolet1 Roger W. Romani
We describe time-tagged observations of the Vela pulsar (PSR B0833−45) with the HST STIS MAMA-UV detectors. Using an optimal extraction technique, we obtain a NUV light curve and crude FUV phase-resolved spectra. The pulse is dominated by complex non-thermal emission at all phases. We obtain approximate spectral indices for the brightest pulse components, relate these to pulsations observed in ...
متن کاملAbsolute Flux Calibration of STIS MAMA Imaging Modes
The absolute flux calibration of STIS MAMA imaging modes is tested by comparison of observed and predicted count rates. As part of this work, we have derived new, wavelength-dependent aperture corrections for MAMA imaging, and have revised the NUVMAMA imaging throughput at short wavelengths. FUV-MAMA imaging modes clearly show a time dependent sensitivity loss that is consistent with the time d...
متن کاملبررسی خصوصیات پایه ای دزیمتریک بلور کلسیم سولفید آلاییده شده با عناصر خاکی کمیاب به عنوان حساسه ی دزیمتر OSL
Background and Aim: Today, OSL (Optically Stimulated Luminescence) dosimetry system based on optical stimulation, includes systems that can meet many requirements for radiation protection in the field of medicine and space. The Calcium Sulfide (CaS) is one of the earth's alkaline sulfide materials which can be used as a detector in this system. In this research, some of the dosimetry propertie...
متن کامل