Calibration of low-temperature ac susceptometers with a copper cylinder standard.

نویسندگان

  • D-X Chen
  • V Skumryev
چکیده

A high-quality low-temperature ac susceptometer is calibrated by comparing the measured ac susceptibility of a copper cylinder with its eddy-current ac susceptibility accurately calculated. Different from conventional calibration techniques that compare the measured results with the known property of a standard sample at certain fixed temperature T, field amplitude H(m), and frequency f, to get a magnitude correction factor, here, the electromagnetic properties of the copper cylinder are unknown and are determined during the calibration of the ac susceptometer in the entire T, H(m), and f range. It is shown that the maximum magnitude error and the maximum phase error of the susceptometer are less than 0.7% and 0.3 degrees, respectively, in the region T=5-300 K and f=111-1111 Hz at H(m)=800 A/m, after a magnitude correction by a constant factor as done in a conventional calibration. However, the magnitude and phase errors can reach 2% and 4.3 degrees at 10,000 and 11 Hz, respectively. Since the errors are reproducible, a large portion of them may be further corrected after a calibration, the procedure for which is given. Conceptual discussions concerning the error sources, comparison with other calibration methods, and applications of ac susceptibility techniques are presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Extraction-Fluorimetric Determination of Low Levels of Copper by 1,7- Diaza-15-Crown-5 and Rose Bengal

A simple and sensitive extraction-fluorimetric method for the determination of copper is reported. The 1,7-diaza-15-crown-5-copper-rose Bengal (DA15C5-Cu-RB) ternary complex is quantitatively extracted into chloroform, diluted with ammoniacal acetone and its fluorescence intensity is measured at 570 nm with excitation at 540 nm. A linear calibration graph was obtained over the copper concen...

متن کامل

Low Cycle Fatigue Simulation of Valve Bridge Region in Cylinder Head Based on Critical Plane Model

The reason of this study is low cycle failure of cast iron cylinder head during the E5 standard durability test. The goal of the present investigation is durability test simulation and low cycle fatigue life evaluation of cast iron cylinder head. With uncouple structural analysis, preloads, thermal and mechanical load and boundary conditions are prescribed to finite element model of the cylinde...

متن کامل

Paramagnetic Reentrance Effect in NS Proximity Cylinders

A scenario for the unusual paramagnetic reentrance behavior at ultra-low temperatures in Nb-Ag, Nb-Au, and Nb-Cu cylinders is presented. For the diamagnetic response down to temperatures of the order 15 mK, the standard theory (quasi-classical approximation) for superconductors appears to work very well, assuming that Ag, Au, and Cu remain in the normal state except for the proximity-induced su...

متن کامل

DNA Sequence Fragment Containing C to A Mutation as a Convenient Mutation Standard for DHPLC Analysis

Objective(s):  Denaturing high performance liquid chromatography (DHPLC) is a high throughput approach for screening DNA sequence variations. To assess oven calibration, cartridge performance, buffer composition and stability, the WAVE Low and High Range Mutation Standards are employed to ensure reproducibility and accuracy of the chromatographic analysis. The purpose of this study was to provi...

متن کامل

Development of a Real-Time Virtual Nitric Oxide Sensor for Light-Duty Diesel Engines

This study describes the development of a semi-physical, real-time nitric oxide (NO) prediction model that is capable of cycle-by-cycle prediction in a light-duty diesel engine. The model utilizes the measured in-cylinder pressure and information obtained from the engine control unit (ECU). From the inputs, the model takes into account the pilot injection burning and mixing, which affects the i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 81 2  شماره 

صفحات  -

تاریخ انتشار 2010