Self-Test Web-Based Pure-Tone Audiometry: Validity Evaluation and Measurement Error Analysis

نویسندگان

  • Mikael Eriksson
  • Marcin Masalski
  • Tomasz Kręcicki
چکیده

BACKGROUND Potential methods of application of self-administered Web-based pure-tone audiometry conducted at home on a PC with a sound card and ordinary headphones depend on the value of measurement error in such tests. OBJECTIVE The aim of this research was to determine the measurement error of the hearing threshold determined in the way described above and to identify and analyze factors influencing its value. METHODS The evaluation of the hearing threshold was made in three series: (1) tests on a clinical audiometer, (2) self-tests done on a specially calibrated computer under the supervision of an audiologist, and (3) self-tests conducted at home. The research was carried out on the group of 51 participants selected from patients of an audiology outpatient clinic. From the group of 51 patients examined in the first two series, the third series was self-administered at home by 37 subjects (73%). RESULTS The average difference between the value of the hearing threshold determined in series 1 and in series 2 was -1.54dB with standard deviation of 7.88dB and a Pearson correlation coefficient of .90. Between the first and third series, these values were -1.35dB±10.66dB and .84, respectively. In series 3, the standard deviation was most influenced by the error connected with the procedure of hearing threshold identification (6.64dB), calibration error (6.19dB), and additionally at the frequency of 250Hz by frequency nonlinearity error (7.28dB). CONCLUSIONS The obtained results confirm the possibility of applying Web-based pure-tone audiometry in screening tests. In the future, modifications of the method leading to the decrease in measurement error can broaden the scope of Web-based pure-tone audiometry application.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biological Calibration for Web-Based Hearing Tests: Evaluation of the Methods

BACKGROUND Online hearing tests conducted in home settings on a personal computer (PC) require prior calibration. Biological calibration consists of approximating the reference sound level via the hearing threshold of a person with normal hearing. OBJECTIVE The objective of this study was to identify the error of the proposed methods of biological calibration, their duration, and the subjecti...

متن کامل

Identification of conductive hearing loss using air conduction tests alone: reliability and validity of an automatic test battery.

OBJECTIVES The primary objective of this study was to determine whether a combination of automatically administered pure-tone audiometry and a tone-in-noise detection task, both delivered via an air conduction (AC) pathway, could reliably and validly predict the presence of a conductive component to the hearing loss. The authors hypothesized that performance on the battery of tests would vary a...

متن کامل

Pure tone audiometry and impedance screening of school entrant children by nurses: evaluation in a practical setting.

BACKGROUND Screening for hearing loss in English children at entry to school (age 5-6 years) is usually by pure tone audiometry sweep undertaken by school nurses. This study aimed to compare the validity and screening rates of pure tone audiometry with impedance screening in these children. METHODS Two stage pure tone audiometry and impedance methods of screening were compared in 610 school e...

متن کامل

Validity of self-reported hearing loss in adults: performance of three single questions.

OBJECTIVE To estimate the validity of three single questions used to assess self-reported hearing loss as compared to pure-tone audiometry in an adult population. METHODS A validity study was performed with a random sub-sample of 188 subjects aged 30 to 65 years, drawn from the fourth wave of a population-based cohort study carried out in Salvador, Northeastern Brazil. Data were collected in ...

متن کامل

Hearing Tests Based on Biologically Calibrated Mobile Devices: Comparison With Pure-Tone Audiometry

BACKGROUND Hearing screening tests based on pure-tone audiometry may be conducted on mobile devices, provided that the devices are specially calibrated for the purpose. Calibration consists of determining the reference sound level and can be performed in relation to the hearing threshold of normal-hearing persons. In the case of devices provided by the manufacturer, together with bundled headph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013