Studies of Nuclear-reactions-in-solid in Titunium Deuteride under Ion Beam Implantation
نویسندگان
چکیده
In order to find the signature of multi-body fusion, experiments of ion-beam implantation were carried out using titanium deuteride target made by the gas-loading method. Up to now, charged particles that are not known in the ordinary beam-target interaction have been observed in the experiment.[1,2,7]
منابع مشابه
Influence of Ni Deposition and Subsequent N+ Ion Implantation at Different Implantation Energies on Nano-Structure and Corrosion Behavior of 316 Stainless Steels
Nickel films of 300 nm thickness were deposited by electron beam evaporation at room temperature on 316 stainless steels. Corrosion studies of Ni coated 316 SS have been performed after N+ ion implantation at different energies of 20, 40, 60 and 80 keV. The structure and surface morphology of the films were evaluated using X-ray diffraction (XRD), atomic force microscope (AFM) an...
متن کاملStudies on 3D Fusion Reactions in TiDx under Ion Beam Implantation
With certain conditions for target-samples and beams, we have identified specific particles (e.g., 4.75MeV tritons and He-particles, and 15.9 MeV deuterons) from 3D fusion reactions with yield ratios [3D]/[2D] on the order of 1E-4 to 1E-3, in contrary to the calculated [3D]/[2D] yield ratio of 1E-30 according to conventional random nuclear reaction theory. The increasing trend of yield ratios i...
متن کاملInfluence of nitrogen ion implantation on the nanostructure and corrosivity of Ni/stainless steel substrates
Ion implantation is a surface modification technology to produce new material on the surface by impingement of high energy ions from the ion accelerator. In this work, AISI 304 stainless steels were coated with 90 nm Ni film by electron beam deposition and implanted by a flow of 5×1017 N cm−2 at 400 K temperature with different implantation energies of 10, 20, 30 and 40 keV. The prepared sample...
متن کاملImpact of Various Beam Parameters on Lateral Scattering in Proton and Carbon-ion Therapy
Background: In radiation therapy with ion beams, lateral distributions of absorbed dose in the tissue are important. Heavy ion therapy, such as carbon-ion therapy, is a novel technique of high-precision external radiotherapy which has advantages over proton therapy in terms of dose locality and biological effectiveness.Methods: In this study, we used Monte Carlo method-based Geant4 toolkit to s...
متن کاملProton beam dosimetry by CR-39 track-etched detector
Background: High and intermediate energy protons are not able to form a track in a solid state nuclear track detector (SSNTD) directly. However, such tracks can be formed through secondary particles created during primary radiation nuclear reactions in a SSNTD. Materials and Methods: The protons with primary energies of 9.6 and 30 MeV available at the cyclotron accelerator with corresponding lo...
متن کامل