Conversion of the chemical concentration of odorous mixtures into odour concentration and odour intensity: a comparison of methods

نویسندگان

  • C. Wu
  • J. Liu
  • P. Zhao
  • M. Piringer
  • G. Schauberger
چکیده

Research Highlights  Concentration of odorous substances as surrogate for odour concentration/intensity  Comparison of conversion methods with various degrees of complexity  Model evaluation by seven VOCs: 23 binary mixtures and 5 mixtures of 7 substances  Model input: odour threshold concentration and the slope of the Weber-Fechner law  No further calibration by olfactometric measurements necessary Wu et al.: Conversion of the chemical concentration of odorous mixtures into odour concentration and odour intensity 2/23 Abstract Continuous odour measurements both of emissions as well as ambient concentrations are seldom realised, mainly because of their high costs. They are therefore often substituted by concentration measurements of odorous substances. Then a conversion of the chemical concentrations C (mg m-3) into odour concentrations C OD (ou E m-3) and odour intensities OI is necessary. Four methods to convert the concentrations of single substances to the odour concentrations and odour intensities of an odorous mixture are investigated: (1) direct use of measured concentrations, (2) the sum of the odour activity value SOAV, (3) the sum of the odour intensities SOI, and (4) the equivalent odour concentration EOC, as a new method. The methods are evaluated with olfactometric measurements of seven substances as well as their mixtures. The results indicate that the SOI and EOC conversion methods deliver reliable values. These methods use not only the odour threshold concentration but also the slope of the Weber-Fechner law to include the sensitivity of the odour perception of the individual substances. They fulfil the criteria of an objective conversion without the need of a further calibration by additional olfactometric measurements.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of odour concentration by TD-GC×GC–TOF-MS and field olfactometry techniques

ABSTRACT Field olfactometry is one of the sensory techniques used to determine odour concentration, in atmospheric air, directly in emission sources. A two-dimensional gas chromatography with time of flight mass spectrometer (GC×GC-TOF-MS) allows performing the chemical characterization of various groups of chemical compounds, even in complex mixtures. Application of these techniques enabled de...

متن کامل

Determination of Odour Interactions of Three-Component Gas Mixtures Using an Electronic Nose

The paper presents an application of an electronic nose prototype comprised of six TGS-type sensors and one PID-type sensor to identify odour interaction phenomena in odorous three-component mixtures. The investigation encompassed eight odorous mixtures-toluene-acetone-triethylamine and formaldehyde-butyric acid-pinene-characterized by different odour intensity and hedonic tone. A principal com...

متن کامل

Determination of Odour Interactions in Gaseous Mixtures Using Electronic Nose Methods with Artificial Neural Networks

This paper presents application of an electronic nose prototype comprised of eight sensors, five TGS-type sensors, two electrochemical sensors and one PID-type sensor, to identify odour interaction phenomenon in two-, three-, four- and five-component odorous mixtures. Typical chemical compounds, such as toluene, acetone, triethylamine, α-pinene and n-butanol, present near municipal landfills an...

متن کامل

Determining Temporary Odour Concentration under Field Conditions – Comparison of Methods

The authors compared two methods of determining odour concentration under field conditions. Twelve series of odour measurements were carried out at a mink farm. Odour concentration was determined using a portable dynamic olfactometer (nasal ranger, st. croix sensory, inc.) and by approximation using the psychophysical Weber-fechner equation of S-logZ on odour intensity results. Odour concentrat...

متن کامل

Odour Samples Degradation During Detention in Tedlar® Bags

In indirect olfactometry analysis, to avoid condensation or adsorption processes during or storage of the sample, containers made of suitable materials should be used. Also, reaction between the chemicals during transport from the source of the odour to the research laboratory is an important process which can influence on examinations' results. Study included determination of the odour and com...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015