Results of 101 aneurysms treated with polyglycolic/polylactic acid microfilament nexus coils compared with historical controls treated with standard coils.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Polyglycolic/polylactic acid (PGLA) addition to bare platinum coils is intended to reduce the reopening rate of coiled intracranial aneurysms. Nexus coils are standard complex platinum coils with interwoven PGLA microfilament threads. We present the clinical results of 101 intracranial aneurysms treated with Nexus coils. MATERIALS AND METHODS Results of coiling of 101 aneurysms treated with Nexus coils were compared with our results of coiling of 120 aneurysms with Guglielmi detachable coils (GDC 10) and 115 with Trufill coils treated between May 2003 and December 2004 with the same treatment protocol. Rate of complications, mean aneurysmal volume, packing attenuation, incomplete aneurysmal occlusion at 6 months, and rates of retreatment were compared. RESULTS Initial occlusion in aneurysms treated with Nexus coils was (near) complete in 97 aneurysms and incomplete in 4 aneurysms. There were no permanent procedural complications (0/95 patients, 0%; 97.5% CI, 0.0% to 3.3%). Mean aneurysmal volume was 180.2 mm(3) (range, 5-1624 mm(3)). Mean packing was 19.4% (range, 7.5% to 38.9%). Six months' angiographic follow-up in 87 of 101 aneurysms showed incomplete occlusion in 14 (16%), and 12 (14%) of those had additional coiling. Mean packing of 19.4% of Nexus coils was significantly lower than 22.9% for GDC 10 and 29.7% for Trufill coils. Other clinical results were not significantly different. CONCLUSION In this series, PGLA microfilament Nexus coils were safe to use with clinical results comparable with those of standard platinum coils. This study gives additional evidence of the lack of beneficial effect of PGLA addition to reduce the reopening rate of coiled intracranial aneurysms.
منابع مشابه
Short-term outcome of intracranial aneurysms treated with polyglycolic acid/lactide copolymer-coated coils compared to historical controls treated with bare platinum coils: a single-center experience.
BACKGROUND AND PURPOSE Aneurysm recanalization is an innate problem in endovascular treatment of aneurysms with coils. A coated coil system, covered with a bioabsorbable polymeric material (polyglycolic acid/lactide copolymer, PGLA), was developed to accelerate intra-aneurysmal clot organization and fibrosis. The purpose of this study was to evaluate the efficacy and safety of the PGLA-coated c...
متن کاملSingle-institution experience with matrix coils in the treatment of intracranial aneurysms: comparison with same-center outcomes with the use of platinum coils.
BACKGROUND AND PURPOSE This study was undertaken to analyze the outcomes and treatment-related complications of the polyglycolic/polylactic acid (PGLA)-coated Matrix platinum coils in the treatment of intracranial aneurysms and compare these results with those derived from the same single-institutional experience with use of uncoated, bare platinum coils. MATERIALS AND METHODS In this study, ...
متن کاملMatrix and bioabsorbable polymeric coils accelerate healing of intracranial aneurysms: long-term experimental study.
BACKGROUND AND PURPOSE Acceleration of intra-aneurysmal clot organization and fibrosis may be a solution to preventing aneurysm recanalization after endovascular treatment. The purpose of this study was to evaluate the short-term efficacy and long-term safety of the new Matrix coil system. METHODS Matrix coils consist of thin platinum coils covered with a bioabsorbable, polymeric material (po...
متن کاملEndovascular occlusion of aneurysms using a new bioactive coil: a matched pair analysis with bare platinum coils.
BACKGROUND AND PURPOSE To assess safety and efficacy data of a new bioactive coil (Cerecyte) which is loaded with polyglycolic acid on the inside of the coil. METHODS Fifty-four patients harboring 55 aneurysms were treated with Cerecyte coils. These aneurysms were matched in localization and size with aneurysms treated with bare platinum coils. RESULTS Periprocedural complications and handl...
متن کاملGuglielmi detachable coils versus matrix coils: a comparison of the immediate posttreatment results of the embolization of 364 cerebral aneurysms in 307 patients: a single-center, single-surgeon experience.
BACKGROUND Matrix coils are based on Gugliemi detachable coils (GDC) but are covered with polyglycolic/polylactic acid. We present our experience regarding the immediate posttreatment results of aneurysm embolization using the 2 coil systems. PATIENTS We embolized 219 aneurysms in 187 patients with the use of GDCs and 145 aneurysms in 120 patients with the use of Matrix coils. Age, sex distri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 29 5 شماره
صفحات -
تاریخ انتشار 2008