Sustained suppression of neointimal proliferation by sirolimus-eluting stents: one-year angiographic and intravascular ultrasound follow-up.
نویسندگان
چکیده
BACKGROUND We have previously reported a virtual absence of neointimal hyperplasia 4 months after implantation of sirolimus-eluting stents. The aim of the present investigation was to determine whether these results are sustained over a period of 1 year. METHODS AND RESULTS Forty-five patients with de novo coronary disease were successfully treated with the implantation of a single sirolimus-eluting Bx VELOCITY stent in São Paulo, Brazil (n=30, 15 fast release [group I, GI] and 15 slow release [GII]) and Rotterdam, The Netherlands (15 slow release, GIII). Angiographic and volumetric intravascular ultrasound (IVUS) follow-up was obtained at 4 and 12 months (GI and GII) and 6 months (GIII). In-stent minimal lumen diameter and percent diameter stenosis remained essentially unchanged in all groups (at 12 months, GI and GII; at 6 months, GIII). Follow-up in-lesion minimal lumen diameter was 2.28 mm (GIII), 2.32 mm (GI), and 2.48 mm (GII). No patient approached the >/=50% diameter stenosis at 1 year by angiography or IVUS assessment, and no edge restenosis was observed. Neointimal hyperplasia, as detected by IVUS, was virtually absent at 6 months (2+/-5% obstruction volume, GIII) and at 12 months (GI=2+/-5% and GII=2+/-3%). CONCLUSIONS This study demonstrates a sustained suppression of neointimal proliferation by sirolimus-eluting Bx VELOCITY stents 1 year after implantation.
منابع مشابه
Persistent inhibition of neointimal hyperplasia after sirolimus-eluting stent implantation: long-term (up to 2 years) clinical, angiographic, and intravascular ultrasound follow-up.
BACKGROUND Early results of sirolimus-eluting stent implantation showed a nearly complete abolition of neointimal hyperplasia. The question remains, however, whether the early promising results will still be evident at long-term follow-up. The objective of our study was to evaluate the efficiency of sirolimus-eluting stent implantation for up to 2 years of follow-up. METHODS AND RESULTS Fifte...
متن کاملFour-year angiographic and intravascular ultrasound follow-up of patients treated with sirolimus-eluting stents.
BACKGROUND Despite the proven superiority of sirolimus-eluting stents (SESs) compared with bare stents in the first year after implantation, long-term outcomes of patients treated with these novel devices remain unknown. Our goal was to evaluate the clinical, angiographic, and intravascular ultrasound (IVUS) outcomes of patients treated with SESs 4 years after implantation. METHODS AND RESULT...
متن کاملTwo-year angiographic and intravascular ultrasound follow-up after implantation of sirolimus-eluting stents in human coronary arteries.
BACKGROUND The safety and efficacy of sirolimus-eluting stenting have been demonstrated, but the outcome of patients treated with this novel technology beyond the first year remains unknown. We sought to evaluate the angiographic, intravascular ultrasound (IVUS), and clinical outcomes of patients treated with sirolimus-eluting stents 2 years after implantation. METHODS AND RESULTS This study ...
متن کاملLate device thrombosis after atrial septal defect closure.
Kay IP, Ligthart JM, Thayssen P, van Den Brand MJ, de Feyter PJ, Serruys PW. Three dimensional intravascular ultrasonic assessment of the local mechanism of restenosis after balloon angioplasty. Heart 2001;85:73–79. 5. Costa MA, Simon DI. Molecular basis of restenosis and drug-eluting stents. Circulation 2005;111:2257–2273. 6. van der Giessen WJ, Lincoff AM, Schwartz RS, van Beusekom HM, Serruy...
متن کاملRandomized comparison of sirolimus and paclitaxel drug-eluting stents for long lesions in the left anterior descending artery: an intravascular ultrasound study.
OBJECTIVES The goal of this work was to verify whether the superiority of the sirolimus-eluting stent (SES) in inhibiting neointimal hyperplasia could be demonstrated in complex coronary lesions. BACKGROUND Both the SES (Cypher, Cordis, Miami Lakes, Florida) and the paclitaxel-eluting stent (PES) (Taxus, Boston Scientific, Natick, Massachusetts) have shown a marked reduction in neointimal hyp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 104 17 شماره
صفحات -
تاریخ انتشار 2001