Development of a deformable lung phantom for the evaluation of deformable registration
نویسندگان
چکیده
The deformable lung phantom was developed to account for the patient breathing motion, and to evaluate for a deformable image registration algorithm. The phantom consisted of an acryl cylinder filled with water and a latex balloon located in the inner space of the cylinder. A silicon membrane was attached to the inferior end of the phantom. This silicon membrane was designed to simulate a real lung diaphragm and to reduce motor workload. This specific design was able to reduce the metal use which may prevent infrared sensing of the real position management (RPM) gating system on 4D CT image acquisition. Verification of intensity based 3D demon deformable registration was based on peak exhale and peak inhale breathing phases. The registration differences ranged from 0.85 mm to 1.47 mm, and accuracy was determined according to inner target deformation. This phantom was able to simulate the features and deformation of real human lung and has the potential for wide application in 4D radiation treatment planning.
منابع مشابه
Evaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملA Novel Framework for Deformable Registration Evaluation and Quality Assurance
Purpose Deformable registration is now routinely used at many radiation oncology centers not only for automatic contouring, but also for diagnostic image registration and dose accumulation. In these applications, it is essential that these registrations are not only characterized with phantom studies, but also be checked on a per-patient basis around the regions where the deformable registratio...
متن کاملTU-AB-BRA-06: BEST IN PHYSICS (JOINT IMAGING-THERAPY): An MRI Compatible Externally and Internally Deformable Lung Motion Phantom for Multi-Modality IGRT.
PURPOSE MRI has become an attractive tool for tumor motion management. Current MR-compatible phantoms are only capable of reproducing translational motion. This study describes the construction and validation of a more realistic, MRI-compatible lung phantom that is deformable internally as well as externally. We demonstrate a radiotherapy application of this phantom by validating the geometric ...
متن کاملA Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images
Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...
متن کاملValidating Dose Uncertainty Estimates Produced by AUTODIRECT: An Automated Program to Evaluate Deformable Image Registration Accuracy
Deformable image registration is a powerful tool for mapping information, such as radiation therapy dose calculations, from one computed tomography image to another. However, deformable image registration is susceptible to mapping errors. Recently, an automated deformable image registration evaluation of confidence tool was proposed to predict voxel-specific deformable image registration dose m...
متن کامل