Cardiac output and systemic transit time dispersion as determinants of circulatory mixing time: a simulation study.

نویسنده

  • Michael Weiss
چکیده

A new approach to characterize the kinetics of intravascular mixing process is presented. The mixing time, defined as the time required for achieving 95% homogeneity, is calculated by numerical simulations using a circulatory model applied to the intravascular marker indocyanine green (ICG). The results suggest that the mixing time is determined by cardiac output and the relative dispersion of transit time distribution across the systemic circulation, whereby the rate of mixing increases with increasing cardiac output and decreasing transit time dispersion, and vice versa. The estimation of plasma volume from simulated ICG dilution data using the backextrapolation method shows that slow mixing is accompanied by an overestimation of blood volume. This error may be negligible for mixing times of less than approximately 3 min but high in disease states characterized by low cardiac output and/or high transit time dispersion. In view of the role of transit time dispersion as determinant of intravascular mixing, it would be interesting to know more about the effect of disease states on systemic transit time dispersion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transit time dispersion in pulmonary and systemic circulation: effects of cardiac output and solute diffusivity.

We present an in vivo method for analyzing the distribution kinetics of physiological markers into their respective distribution volumes utilizing information provided by the relative dispersion of transit times. Arterial concentration-time curves of markers of the vascular space [indocyanine green (ICG)], extracellular fluid (inulin), and total body water (antipyrine) measured in awake dogs un...

متن کامل

Cardiac output, oxygen consumption and renal blood flow in essential hypertension.

Cardiac output, oxygen consumption, total blood volume and mean circulatory transit time were investigated at rest in men with sustained essential hypertension in comparison with normal subjects of the same age and sex. In normal subjects and in patients with hypertension, oxygen consumption was positively correlated to cardiac output. In hypertensives, the slope of the curve was significantly ...

متن کامل

A physiologically based approach for the estimation of recirculatory parameters.

Indicator dilution studies are used to provide estimates for several physiological parameters such as cardiac output as well as intra- and extravascular volumes. This study introduces a novel technique for the estimation of recirculatory parameters. A mathematical model based on a dispersion-convection partial differential equation (PDE), derived from the fractal geometry of the vascular tree a...

متن کامل

Fluid Dynamics in a Copper Converter: an Investigation on Mixing Phenomena in an Experimental Model

In this study, the mixing phenomena and fluid dynamics in a copper converter have been experimentally investigated using a physical model. The physical model is a 1:5 horizontal tank made of Plexiglas. The mixing phenomena have been characterized by experimentally measuring the mixing time using a tracer dispersion technique. Moreover, the effects of the air flow rate and lance submergence on t...

متن کامل

مانیتورینگ همودینامیک به روش غیر تهاجمی در بخش مراقبت های ویژه: مقاله مروری

Aim and background : Hemodynamic monitoring of critical patients in intensive units is the cornstone of care. It constitutes an extensive part of care and is helpful in determination of the causes and the response to treatment of hemodynamic instability. Aim of this review articale is to investigate of the Non invasive hemodynamic monitoring in critical care units. Materials and Methods:61 art...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 107 2  شماره 

صفحات  -

تاریخ انتشار 2009