Correlation of Air Displacement Plethysmography with Alternative Body Fat Measurement Techniques in Men and Women

نویسندگان

  • BRITTANY L. REINERT
  • ROBERTA POHLMAN
  • LYNN HARTZLER
چکیده

Obesity has reached epidemic proportions with serious health consequences. Techniques used to measure body fat (BF) yield variable BF estimates, and this variability may lead to underestimation or overestimation of BF and subsequent treatment options. The measurements that are most accurate (Dual-Energy X-ray Absorptiometry (DEXA) and Air Displacement Plethysmography (ADP)) are expensive and often unavailable. The purpose of this study is to find the commonly available BF measurement that is the most accurate and practical for individual body types in the general population and compare these measurements to ADP (BOD POD®) as the standard. Field measurements include skinfolds (SKF), upper, lower, and whole body bioelectrical impedance (BI), waist and hip circumference ratios, body mass index calculations (BMI), and ADP. Our data indicate that BI is the least accurate measurement of body fat in males and females (paired t-tests of % body fat: BI vs. ADP, p0.05). However, preliminary data suggest female- specific SKF equations more accurately predict body fat in obese males than male-specific SKF equations. Given the current obesity trends, it is imperative to update these formulae to accurately reflect the current population.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A 4-compartment model based validation of air displacement plethysmography, dual energy X-ray absorptiometry, skinfold technique & bio-electrical impedance for measuring body fat in Indian adults

BACKGROUND & OBJECTIVES Many methods are available for measuring body fat of an individual, each having its own advantages and limitations. The primary objective of the present study was to validate body fat estimates from individual methods using the 4-compartment (4C) model as reference. The second objective was to obtain estimates of hydration of fat free mass (FFM) using the 4C model. MET...

متن کامل

Body composition assessment in extreme obesity and after massive weight loss induced by gastric bypass surgery.

Body composition methods were examined in 20 women [body mass index (BMI) 48.7 +/- 8.8 kg/m(2)] before and after weight loss [-44.8 +/- 14.6 (SD) kg] after gastric bypass (GBP) surgery. The reference method, a three-compartment (3C) model using body density by air displacement plethysmography and total body water (TBW) by H(2)18O dilution (3C-H(2)18O), showed a decrease in percent body fat (%BF...

متن کامل

Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults

BACKGROUND The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA) requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displacement plethysmography (ADP) as standard method to measure body composition in Mexican adult men and w...

متن کامل

Comparison of air-displacement plethysmography with hydrostatic weighing and bioelectrical impedance analysis for the assessment of body composition in healthy adults.

BACKGROUND Over the past decade, considerable attention has been paid to accurately measuring body composition in diverse populations. Recently, the use of air-displacement plethysmography (AP) was proposed as an accurate, comfortable, and accessible method of body-composition analysis. OBJECTIVE The purpose of this study was to compare measurements of percentage body fat (%BF) by AP and 2 ot...

متن کامل

Length-free near infrared measurement of newborn malnutrition

Under-nutrition in neonates can cause immediate mortality, impaired cognitive development and early onset adult disease. Body fat percentage measured using air-displacement-plethysmography has been found to better indicate under-nutrition than conventional birth weight percentiles. However, air-displacement-plethysmography equipment is expensive and non-portable, so is not suited for use in dev...

متن کامل