A Simple Method to Measure Renal Function in Swine by the Plasma Clearance of Iohexol
نویسندگان
چکیده
There is no simple method to measure glomerular filtration rate (GFR) in swine, an established model for studying renal disease. We developed a protocol to measure GFR in conscious swine by using the plasma clearance of iohexol. We used two groups, test and validation, with eight animals each. Ten milliliters of iohexol (6.47 g) was injected into the marginal auricular vein and blood samples (3 mL) were collected from the orbital sinus at different points after injection. GFR was determined using two models: two-compartment (CL2: all samples) and one-compartment (CL1: the last six samples). In the test group, CL1 overestimated CL2 by ~30%: CL2 = 245 ± 93 and CL1 = 308 ± 123 mL/min. This error was corrected by a first-order polynomial quadratic equation to CL1, which was considered the simplified method: SM = -47.909 + (1.176xCL1) - (0.00063968xCL1²). The SM showed narrow limits of agreement with CL2, a concordance correlation of 0.97, and a total deviation index of 14.73%. Similar results were obtained for the validation group. This protocol is reliable, reproducible, can be performed in conscious animals, uses a single dose of the marker, and requires a reduced number of samples, and avoids urine collection. Finally, it presents a significant improvement in animal welfare conditions and handling necessities in experimental trials.
منابع مشابه
Swine by the Plasma Clearance of Iohexol
There is no simple method to measure glomerular filtration rate (GFR) in swine, an 15 established model to study renal disease. We developed a protocol to measure GFR in conscious 16 swine with the plasma clearance of iohexol. We used two groups: testing and validation, of 8 17 animals each. Ten milliliters of iohexol (6.47 g) were injected by the marginal auricular vein and 18 blood samples (3...
متن کاملValidation of a routine two‐sample iohexol plasma clearance assessment of GFR and an evaluation of common endogenous markers in a rat model of CKD
Endogenous markers of kidney function are insensitive to early declines in glomerular filtration rate (GFR) and in rodent models, validated, practical alternatives are unavailable. In this study, we determined GFR by modeling the plasma clearance of two compounds, iohexol and inulin, and compared the findings to common endogenous markers. All plasma clearance methods of both iohexol and inulin ...
متن کاملIohexol plasma clearance for measuring glomerular filtration rate in clinical practice and research: a review. Part 1: How to measure glomerular filtration rate with iohexol?
While there is general agreement on the necessity to measure glomerular filtration rate (GFR) in many clinical situations, there is less agreement on the best method to achieve this purpose. As the gold standard method for GFR determination, urinary (or renal) clearance of inulin, fades into the background due to inconvenience and high cost, a diversity of filtration markers and protocols compe...
متن کاملA camera based calculation of 99mTc-MAG3 clearance using conjugate views method [Persian]
Background: Measurement of absolute or differential renal function using radiotracers plays an important role in the clinical management of various renal diseases. Gamma camera quantitative methods in approximation of renal clearance may potentially be as accurate as plasma clearance methods. However some critical factors such as kidney depth and background counts are still troublesome in...
متن کاملIohexol Clearance for Determination of Glomerular Filtration Rate in Rats Induced to Acute Renal Failure
INTRODUCTION The glomerular filtration rate (GFR) is considered an especially important tool for the measurement of renal function. Inulin clearance (InCl) is the classic reference method for this purpose, although it is associated with a number of disadvantages; thus, other markers have been proposed, including iohexol. Determination of iohexol clearance (IoCl) has been established for clinica...