Validation of tetrapolar bioelectrical impedance method to assess human body composition.

نویسندگان

  • H C Lukaski
  • W W Bolonchuk
  • C B Hall
  • W A Siders
چکیده

This study was conducted to validate the relationship between bioelectrical conductance (ht2/R) and densitometrically determined fat-free mass, and to compare the prediction errors of body fatness derived from the tetrapolar impedance method and skinfold thicknesses, relative to hydrodensitometry. One-hundred and fourteen male and female subjects, aged 18-50 yr, with a wide range of fat-free mass (34-96 kg) and percent body fat (4-41%), participated. For males, densitometrically determined fat-free mass was correlated highly (r = 0.979), with fat-free mass predicted from tetrapolar conductance measures using an equation developed for males in a previous study. For females, the correlation between measured fat-free mass and values predicted from the combined (previous and present male data) equation for men also was strong (r = 0.954). The regression coefficients in the male and female regression equations were not significantly different. Relative to hydrodensitometry, the impedance method had a lower predictive error or standard error of the estimates of estimating body fatness than did a standard anthropometric technique (2.7 vs. 3.9%). Therefore this study establishes the validity and reliability of the tetrapolar impedance method for use in assessment of body composition in healthy humans.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy of bioelectrical impedance consumer devices for measurement of body composition in comparison to whole body magnetic resonance imaging and dual X-ray absorptiometry.

OBJECTIVE To compare body composition determined by bioelectrical impedance (BIA) consumer devices against criterion estimates determined by whole body magnetic resonance imaging (MRI) and dual energy X-ray absorptiometry (DXA) in healthy normal weight, overweight and obese adults. METHODS In 106 adults (54 females, 52 males, age 54.2 +/- 16.1 years, BMI 25.8 +/- 4.4 kg/m(2)) fat mass (FM), s...

متن کامل

A prediction equation for total body water from bioelectrical impedance in Japanese children.

Total body water (TBW) measured by isotope dilution techniques can be used to assess body composition safely and accurately in children. Unfortunately, this method is not readily available for most research projects, particularly when working with large groups of people, because the equipment is complicated and highly specialized. Bioelectrical impedance (BI) method is a simple, quick, and inex...

متن کامل

Phase Angle Measurement in Healthy Human Subjects through Bio-Impedance Analysis

Objective(s)Bioelectrical impedance is the measure of impedance of the body. Impedance consists of electric resistance and reactance. Phase angle (PA) is the tan value of the ratio of reactance versus electric resistance. PA depends on cell membrane integrity and on body cell mass. There exists a correlation between PA values and body cell mass.The objective of this study was to compare the PA ...

متن کامل

Evaluation of the predictive capacity of vertical segmental tetrapolar bioimpedance for excess weight detection in adolescents.

OBJECTIVE To analyze the predictive capacity of the vertical segmental tetrapolar bioimpedance apparatus in the detection of excess weight in adolescents, using tetrapolar bioelectrical impedance as a reference. METHODS This was a cross-sectional study conducted with 411 students aged between 10 and 14 years, of both genders, enrolled in public and private schools, selected by a simple and st...

متن کامل

Bioelectrical impedance and strength measurements in patients with heart failure: comparison with functional class.

OBJECTIVE Patients with chronic heart failure (HF) develop important changes in body composition. Nevertheless, the usual methods of body composition assessment can be misleading in patients with HF because tissue hydration is altered. Bioelectrical impedance vector analysis (BIVA) works without making any assumption about constant soft tissue hydration. In this study, patients with HF and syst...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 60 4  شماره 

صفحات  -

تاریخ انتشار 1986