Image reconstruction and the effect on dose calculation for hip prostheses.

نویسندگان

  • Paul J Keall
  • Leah B Chock
  • Robert Jeraj
  • Jeffrey V Siebers
  • Radhe Mohan
چکیده

High atomic number inserts, such as hip prostheses and dental fillings, cause streak artifacts on computed tomography (CT) images when filtered back-projection (FBP) methods are used. These streak artifacts severely degrade our ability to differentiate the tumor volume. Also, incorrect Hounsfield numbers yield incorrect electron density information that may lead to erroneous dose calculations, and, as a result, compromise clinical outcomes. The aim of this research was to evaluate the dosimetric consequences of artifacts during radiotherapy planning of a prostate patient containing a hip prosthesis. The CT numbers corresponding to an iron prosthesis were inserted into the right femoral head of an existing CT image set. This artifact-free image was used as the standard image set. CT projections through the image set formed the sinogram, from which filtered back projection and iterative deblurring methods were used to create reconstructed image sets. These reconstructed image sets contained artifacts. Prostate treatment plans were then calculated using a Monte Carlo system for the standard and reconstructed CT image sets. Close to the prosthesis, the CT numbers between the reconstructed and standard image sets differed substantially. However, because the CT number differences covered only a small area, the dose distributions on the reconstructed and standard image sets were not significantly different. The dose-volume histograms for the prostate, rectum, and bladder were virtually identical. Our results indicate that even though CT image artifacts restrict our ability to differentiate tumors and critical structures, the dose distributions for a prostate plan containing a hip prosthesis, calculated on both artifact-free image sets and image sets containing artifacts, are not significantly different.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast System Matrix Calculation in CT Iterative Reconstruction

Introduction: Iterative reconstruction techniques provide better image quality and have the potential for reconstructions with lower imaging dose than classical methods in computed tomography (CT). However, the computational speed is major concern for these iterative techniques. The system matrix calculation during the forward- and back projection is one of the most time- cons...

متن کامل

Optimization of tomotherapy treatment planning for patients with bilateral hip prostheses

BACKGROUND To determine the effect of different imaging options and the most efficient imaging strategy for treatment planning of patients with hip prostheses. METHODS The planning kilovoltage CT (kVCT) and daily megavoltage CT (MVCT) studies for three prostate cancer patients with bilateral hip prostheses were used for creating hybrid kVCT/MVCT image sets. Treatment plans were created for kV...

متن کامل

Investigating the effects of different kernels used for CT image reconstruction on dose distributions in treatment planning of kidney cancer radiotherapy

Introduction: The quality of CT images used for treatment planning of cancer patients is an important issue in accurate outlining of the tumor volume and organs at risk. Different kernels in CT scanner systems are available for improving the image quality. Applying these kernels  on   CT  images  will  change   the   CT  numbers  and  electron   density   of   tissues, conse...

متن کامل

Radiotherapy dose calculations in the presence of hip prostheses.

The high density and atomic number of hip prostheses for patients undergoing pelvic radiotherapy challenge our ability to accurately calculate dose. A new clinical dose calculation algorithm, Monte Carlo, will allow accurate calculation of the radiation transport both within and beyond hip prostheses. The aim of this research was to investigate, for both phantom and patient geometries, the capa...

متن کامل

Effect of Post-Reconstruction Gaussian Filtering on Image Quality and Myocardial Blood Flow Measurement with N-13 Ammonia PET

Objective(s): In order to evaluate the effect of post-reconstruction Gaussian filtering on image quality and myocardial blood flow (MBF) measurement by dynamic N-13 ammonia positron emission tomography (PET), we compared various reconstruction and filtering methods with image characteristics. Methods: Dynamic PET images of three patients with coronary artery disease (male-female ratio of 2:1; a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical dosimetry : official journal of the American Association of Medical Dosimetrists

دوره 28 2  شماره 

صفحات  -

تاریخ انتشار 2003