Assessing the commutability of reference material formats for the harmonization of amyloid-β measurements.

نویسندگان

  • Maria Bjerke
  • Ulf Andreasson
  • Julia Kuhlmann
  • Erik Portelius
  • Josef Pannee
  • Piotr Lewczuk
  • Robert M Umek
  • Eugeen Vanmechelen
  • Hugo Vanderstichele
  • Erik Stoops
  • Jennifer Lewis
  • Manu Vandijck
  • Vesna Kostanjevecki
  • Andreas Jeromin
  • Salvatore J Salamone
  • Oliver Schmidt
  • Anja Matzen
  • Kairat Madin
  • Udo Eichenlaub
  • Tobias Bittner
  • Leslie M Shaw
  • Ingrid Zegers
  • Henrik Zetterberg
  • Kaj Blennow
چکیده

BACKGROUND The cerebrospinal fluid (CSF) amyloid-β (Aβ42) peptide is an important biomarker for Alzheimer's disease (AD). Variability in measured Aβ42 concentrations at different laboratories may be overcome by standardization and establishing traceability to a reference system. Candidate certified reference materials (CRMs) are validated herein for this purpose. METHODS Commutability of 16 candidate CRM formats was assessed across five CSF Aβ42 immunoassays and one mass spectrometry (MS) method in a set of 48 individual clinical CSF samples. Promising candidate CRM formats (neat CSF and CSF spiked with Aβ42) were identified and subjected to validation across eight (Elecsys, EUROIMMUN, IBL, INNO-BIA AlzBio3, INNOTEST, MSD, Simoa, and Saladax) immunoassays and the MS method in 32 individual CSF samples. Commutability was evaluated by Passing-Bablok regression and the candidate CRM termed commutable when found within the prediction interval (PI). The relative distance to the regression line was assessed. RESULTS The neat CSF candidate CRM format was commutable for almost all method comparisons, except for the Simoa/MSD, Simoa/MS and MS/IBL where it was found just outside the 95% PI. However, the neat CSF was found within 5% relative distance to the regression line for MS/IBL, between 5% and 10% for Simoa/MS and between 10% and 15% for Simoa/MSD comparisons. CONCLUSIONS The neat CSF candidate CRM format was commutable for 33 of 36 method comparisons, only one comparison more than expected given the 95% PI acceptance limit. We conclude that the neat CSF candidate CRM can be used for value assignment of the kit calibrators for the different Aβ42 methods.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Toward standardization of cardiac troponin I measurements part II: assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays.

BACKGROUND Cardiac tropoin I (cTnI) measurements show an approximately 20- to 40-fold difference between assays, and better standardization and harmonization are needed. Toward this goal, the AACC cTnI Standardization Committee collaborated with the National Institute of Standards and Technology (NIST) in an earlier study to select 2 candidate reference materials (cRMs). METHODS Two troponin ...

متن کامل

Synthesis and biological assessment of 2-hydroxyiminoethanones as anti-inflammatory and β-amyloid aggregation inhibitors

Alzheimer’s disease (AD) is a neuroinflammatory based pathologic state in which β-amyloid aggregates are a major devastating agents. In this study, a series of 2-hydroxyiminoethanones were synthesized and evaluated as anti-inflammatory in carrageenan and formalin tests and inhibitors of β-amyloid aggregation. Compounds 1-10b were synthesized through a two-step reaction. Results: Compounds 1-5b ...

متن کامل

Specimen materials, target values and commutability for external quality assessment (proficiency testing) schemes.

BACKGROUND The objective of external quality assessment is to evaluate clinical acceptability of laboratory results. It is desirable to evaluate intermethod harmonization and traceability to a reference system. METHODS Conventional matrix-modified processed materials are used in most programs, because they can be produced in large quantities, can have multiple abnormal analytes in the same vi...

متن کامل

Synthesis and biological assessment of 2-hydroxyiminoethanones as anti-inflammatory and β-amyloid aggregation inhibitors

Alzheimer’s disease (AD) is a neuroinflammatory based pathologic state in which β-amyloid aggregates are a major devastating agents. In this study, a series of 2-hydroxyiminoethanones were synthesized and evaluated as anti-inflammatory in carrageenan and formalin tests and inhibitors of β-amyloid aggregation. Compounds 1-10b were synthesized through a two-step reaction. Results: Compounds 1-5b ...

متن کامل

The importance of commutability of reference materials used as calibrators: the example of ceruloplasmin.

BACKGROUND Different methods for ceruloplasmin tend to give different results in external quality assessment schemes. During the production of the certified reference material ERM-DA470k/IFCC discrepant measurement results were also found for ceruloplasmin measured with different methods, and consequently the protein could not be certified in the material. METHODS We performed a commutability...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry and laboratory medicine

دوره 54 7  شماره 

صفحات  -

تاریخ انتشار 2016