Pumping capacity and reliability of cryogenic micro-pump for micro-satellite applications
نویسندگان
چکیده
In micro-satellites, delicate instruments are compacted into a limited space. This raises concerns of active cooling and remote cooling. Silicon based micro-pump arrays are employed thanks to manufacturing simplicity, a small cryogen charge, etc, and keep the instruments within a narrow cryogenic temperature range. The pumping capacity and reliability of the micro-pump are critical in terms of heat balance calculation and lifetime evaluation. The pumping capacity is associated with the diaphragm deflection while the reliability is associated with stress and fatigue. Both of them heavily depend on the silicon diaphragm, one of the key components. This paper examines the pumping capacity and reliability of the micro-pump under cryogenic temperature for micro-satellite applications. In this work, differential pressure was used for the actuation of a single-crystal silicon diaphragm. Diaphragm deflection and stress distribution were achieved using interferometry and micro-Raman spectroscopy, respectively. As a result, smaller pumping capacity was derived under cryogenic temperature, compared to that under room temperature, indicating a stiffer material. From stress mapping, the edge centers were believed to be the most vulnerable to fracture, which was further validated by analyzing the fracture diaphragm. Moreover, a fatigue testing was conducted for 1.8 million cycles with no damage found, verifying silicon as a viable material for long time operation in a cryogenic environment. (Some figures in this article are in colour only in the electronic version)
منابع مشابه
Micro Magnetic Stir-bars Integrated in Parylene Su~ace-micromachined Channels for Mixing and Pumping
We report the design, fabrication, and testing results of a micro magnetic stir-bar monolithically integrated in Parylene surface-micromachined channels with small tip-tochannel clearance. We demonstrated two applications of such stir bars: mixing and pumping.
متن کاملChip integrated micro cooling system for high heat flux electronic cooling applications
Rapid development in VLSI Technology anticipates an urgent need for new micro cooling strategies for high heat flux electronic chips. This paper presents a novel high efficiency micropump/evaporator, based on electrohydrodynamic (EHD) forces, high heat flux electronic sensors. The device incorporates a MEMS-based active micro-evaporative surface and temperature sensors into a single package tha...
متن کاملSurface micromachined electrostatically actuated micro peristaltic pump.
An electrostatically actuated micro peristaltic pump is reported. The micro pump is entirely surface micromachined using a multilayer parylene technology. Taking advantage of the multilayer technology, the micro pump design enables the pumped fluid to be isolated from the electric field. Electrostatic actuation of the parylene membrane using both DC and AC voltages was demonstrated and applied ...
متن کاملIncreasing pumping efficiency in a micro throttle pump by enhancing displacement amplification in an elastomeric substrate
Fluid transport is accomplished in a micro throttle pump (MTP) by alternating deformation of a micro channel cast into a PDMS elastomeric substrate. The active deformation is achieved using a bimorph PZT piezoelectric disk actuator bonded to a glass diaphragm. The bimorph PZT deflects the diaphragm as well as alternately pushing and pulling the elastomer layer providing displacement amplificati...
متن کاملA valveless micro impedance pump driven by electromagnetic actuation
Over the past two decades, a variety of micropumps have been explored for various applications in microfluidics such as control of picoand nanoliter flows for drug delivery as well as chemical mixing and analysis. We present the fabrication and preliminary experimental studies of flow performance on the micro impedance pump, a previously unexplored method of pumping fluid on the microscale. The...