Design considerations for fire resistance of lightweight-framed assemblies

نویسندگان

  • N. Bénichou
  • M. A. Sultan
چکیده

The effects of a number of design parameters have been investigated including the types of cavity insulation, resilient channels, gypsum board thickness, the number of gypsum board layers, stud arrangements, and type of framing. The results have shown that the main factors that affected the performance of stud wall assemblies were the type of insulation and the number of gypsum board layers. In addition, a description on how the information gathered from this study will be used to benefit practitioners, builders and regulators in choosing suitable assemblies for their designs is also presented.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solar Energy System Design of Ultralight Aircraft for Smoke Detection and Fire Alarm Proposes

Abstract: The purpose of this paper is to design and evaluate the construction of a lightweight solar aircraft that is capable of flying continuously for 24 hours relying solely on solar energy. The required energy is absorbed during the day by solar panels, some is used directly for flight, and the excess energy is stored in the aircraft battery for overnight flight. The aircraft will then be ...

متن کامل

Experimental Study on Fire Resistance Performance of a Hollow Slab Using a Lightweight Hollow Sphere

This study evaluates the fire resistance performance (1–2h) of a reinforced concrete (RC) structure-void slab using a lightweight hollow sphere, which can reduce the unnecessary dynamic of removing the central concrete. For this experiment, we set up the depth of the concrete cover, live load, and span length as the factors. The result comes out with 50 mm cover depth of the RC structure hollow...

متن کامل

Investigation of mechanical and durability properties of lightweight concrete containing Pumice

In this research, the effect of the cement, sand, and pumice mixture on the durability of lightweight concrete is investigated. The intention of this paper is to replace a certain amount of the pumice percentage as an alternative option of the cement and pumice sand aggregate with conventional sand components. The experimental results include compressive strength, ion-chloride emission factor (...

متن کامل

An Aerosol Generator for Fire Depression - Design Considerations and Experimental Study

A new lightweight gas-particle mixture generator for fire-extinguishing purposes is designed such as to keep the generator and aerosol temperatures low by including a Phase Change Materials (PCM) component. The new generator performances have been studied experimentally and compared to the corresponding performances of a traditional design. The temperature evolution profiles of this gas-particl...

متن کامل

The Fire Performance of Exposed Timber Panels

Cross-laminated timber is increasingly being used in the construction of high-rise buildings due to its simple manufacturing system. In term of fire resistance, cross-laminated timber panels are promoted as having excellent fire resistance, comparable to that of non-combustible materials and to heavy timber construction, due to the ability of thick wood assemblies to char slowly at a predictabl...