Simple flow-injection system for the simultaneous determination of nitrite and nitrate in water samples.

نویسندگان

  • Rodjana Burakham
  • Mitsuko Oshima
  • Kate Grudpan
  • Shoji Motomizu
چکیده

A novel spectrophotometric reaction system was developed for the determination of nitrite as well as nitrate in water samples, and was applied to a flow-injection analysis (FIA). The spectrophotometric flow-injection system coupled with a copperised cadmium reductor column was proposed. The detection was based on the nitrosation reaction between nitrite ion and phloroglucinol (1,3,5-trihydroxybenzene), a commercially available phenolic compound. Sample injected into a carrier stream was split into two streams at the Y-shaped connector. One of the streams merged directly and reacted with the reagent stream: nitrite ion in the samples was detected. The other stream was passed through the copperised cadmium reductor column, where the reduction of nitrate to nitrite occurred, and the sample zone was then mixed with the reagent stream and passed through the detector: the sum of nitrate and nitrite was detected. The optimised conditions allow a linear calibration range of 0.03-0.30mug NO(2)(-)-Nml(-1) and 0.10-1.00mug NO(3)(-)-Nml(-1). The detection limits for nitrite and nitrate, defined as three times the standard deviation of measured blanks are 2.9ng NO(2)(-)-Nml(-1) and 2.3ng NO(3)(-)-Nml(-1), respectively. Up to 20 samples can be analyzed per hour with a relative standard deviation of less than 1.5%. The proposed method could be applied successfully to the simultaneous determination of nitrite and nitrate in water samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of nitrite and nitrate in water samples by an automated hydrodynamic sequential injection method.

An automated hydrodynamic sequential injection (HSI) system with spectrophotometric detection was developed. Thanks to the hydrodynamic injection principle, simple devices can be used for introducing reproducible microliter volumes of both sample and reagent into the flow channel to form stacked zones in a similar fashion to those in a sequential injection system. The zones were then pushed to ...

متن کامل

Spectrophotometric simultaneous determination of nitrite, nitrate and ammonium in soils by flow injection analysis.

A new rapid flow injection procedure for the simultaneous determination of nitrate, nitrite and ammonium in single flow injection analysis system is proposed. The procedure combines on-line reduction of nitrate to nitrite and oxidation of ammonium to nitrite with spectrophotometric detection of nitrite by using the Griess-Ilosvay reaction. The formed azo dye was measured at 543 nm. The influenc...

متن کامل

Simultaneous determination of nitrite, nitrate, sulphate and phenolic compounds, by sequential injection analysis, in wastewaters

A sequential injection analysis (SIA) system for the simultaneous determination of nitrite, nitrate, sulphate and phenolic compounds, in wastewaters has been developed. The nitrite determination is based on the Griess-Llosvay reaction. Nitrate is previously reduced to nitrite in a copperized cadmium column and analyzed as nitrite. The sulphate determination is based on the turbidimetric determi...

متن کامل

Simultaneous spectrophotometric determination of nitrite and nitrate by flow-injection analysis.

An automatic direct spectrophotometric method for the simultaneous determination of nitrite and nitrate by flow-injection analysis has been developed. Nitrite reacts with 3-nitroaniline in the presence of hydrochloric acid (0.96-1.8 M HCl or pH 0.5-0.7) to form a diazonium cation, which is subsequently coupled with N-(1-naphthyl)-ethylenediamine dihydrochloride to form a stable purple azo dye, ...

متن کامل

Determination of Nitrite and Nitrate in Natural Waters Using Flow Injection with Spectrophotometric Detection

A simple and sensitive flow injection spectrophotometric method is reported for the room temperature determination of nitrite and nitrate based on the Griess reaction and a copperised cadmium column for reduction of nitrate. Calibration graphs were linear over the range 2 – 1000 μg N L (R = 0.9997 and 0.9999, n = 9) with a limit of detection (3 s.d.) of 1.0 μg N L and relative standard deviatio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 64 5  شماره 

صفحات  -

تاریخ انتشار 2004