Axial penile rigidity influences patient and partner satisfaction after penile prosthesis implantation.
نویسندگان
چکیده
INTRODUCTION Penile prosthesis implantation is one of the treatment choices that is kept for patients who were not satisfied with other treatments. Although penile prosthesis satisfaction rates are higher, there are some dissatisfied patients. The patients’ reasons are mostly shortness and softness of implanted prosthesis. It was previously demonstrated that penile axial rigidity of more than 500 grams is enough for successful vaginal intromission. To our knowledge, there is no study comparing axial rigidity of penile prosthesis and satisfaction. OBJECTIVES The aim of this study was to examine whether axial rigidity of penile prosthesis had impact on patient and partner satisfaction. MATERIALS AND METHODS We enrolled one hundred patients who were implanted penile prosthesis before to evaluate their penile axial rigidity. We used Rigidometry (by using the digital inflection rigidometer) to assess the minimal axial pressure to bend the implanted penis. RESULTS We demonstrated that mean axial pressure to bend the implanted penis was 984.8 ± 268.7 grams. Overall satisfaction score with the penile prosthesis implant was 4.55 and 4.49 (out of 5) in patients and partners, respectively. In total, seven men were unsatisfied with their implant and reported a mean satisfaction score of 0.6 ± 0.48 (out of 5). All prostheses types showed good and more than 500 grams axial rigidity. The patients with Ambicor type, which were buckled at about 710.5 grams, showed worse satisfaction rates in comparison to other prostheses in two patients. Digital inflection rigidometer results of other penile prosthesis types in unsatisfied patient were 842.0, 872.0, 887.0 and 920 g. in CX700, Titan, Genesis and Titan OTR, respectively. CONCLUSION We demonstrated that dissatisfaction rate was highest in Ambicor prosthesis implanted patients. Additionally, patients with 3-piece penile prosthesis were more satisfied than 2-piece or malleable ones, interestingly, although some cases had lower axial rigidity results.
منابع مشابه
Self and partner satisfaction rates after 3 part inflatable penile prosthesis implantation.
OBJECTIVE To evaluate and present satisfaction rates of our patients and their partners after 3 part inflatable penile prosthesis implantation. MATERIALS AND METHODS We searched our hospital electronic data for patients who underwent inflatable penile prosthesis implantation between January 2008 and July 2013. Computer and archived file data were used to get information and reach the patients...
متن کاملPatient and partner outcome of inflatable and semi-rigid penile prosthesis in a single institution
INTRODUCTION Penile prostheses are subject to a continuous development and have gained better mechanical reliability and safety during the last decades. In this study, we aimed to investigate the outcomes and satisfaction rates of inflatable penile prosthesis (IPP) and semirigid penile prosthesis (SPP) implantation. MATERIALS AND METHODS From August 2001 to June 2012, 257 men with erectile dy...
متن کاملEvaluation of Satisfaction and Axial Rigidity with Titan XL Cylinders
The inflatable penile prosthesis (IPP) has high patient satisfaction rates and good mechanical reliability rates in multiple studies. The number one patient compliant at six months is penile length. Recently, new technique for aggressive sizing of the cylinders has been published on in the literature. One IPP company has produced a new product that has longer length cylinders (XL) than those av...
متن کاملRe: Intermediate term assessment of the reliability, function and patient satisfaction with the AMS700 ultrex penile prosthesis.
PURPOSE The AMS700 Ultrex penile prosthesis is an example of the design changes that penile prostheses have undergone to improve mechanical reliability. Few studies have reviewed an overall experience with the AMS700 Ultrex prosthesis. We review patient outcomes, surgical complications, and Ultrex cylinder intermediate term mechanical reliability and function. MATERIALS AND METHODS Between Ma...
متن کاملRe: Surgical Treatment of Erectile Dysfunction and Peyronie's Disease Using Malleable Prosthesis.
PURPOSE Peyronie's disease (PD) is a condition of middle aged men and frequently accompanied by erectile dysfunction (ED) which was attributed to penile deformity, vascular pathology and psychological components. The implantation of semi-rigid penile prosthesis allows for these patients to undergo a simple procedure aimed at correction both penile deformity and ED. The aim of this study was to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Archivio italiano di urologia, andrologia : organo ufficiale [di] Societa italiana di ecografia urologica e nefrologica
دوره 85 3 شماره
صفحات -
تاریخ انتشار 2013