Performance of Rapid Point-of-Care and Laboratory Tests for Acute and Established HIV Infection in San Francisco

نویسندگان

  • Christopher D. Pilcher
  • Brian Louie
  • Shelley Facente
  • Sheila Keating
  • John Hackett
  • Ana Vallari
  • Chris Hall
  • Teri Dowling
  • Michael P. Busch
  • Jeffrey D. Klausner
  • Frederick M. Hecht
  • Sally Liska
  • Mark W. Pandori
چکیده

BACKGROUND Current laboratory and point-of-care tests for HIV detect different analytes and use different sample types. Some have fast turnaround times (<1 hour). We investigated how HIV test choice could impact case finding by testing programs. METHODS We analyzed 21,234 consecutive HIV tests with venous blood obtained by San Francisco HIV testing programs from 2003 to 2008. For a subset, oral fluid (n = 6446) or fingerstick blood (n = 8127) samples were also obtained for rapid testing. In all cases, HIV status was determined using an HIV antibody-plus-RNA test algorithm. We assessed how the screening antibody tests performed individually versus the gold standard of the full algorithm. We then evaluated the potential ability of other tests (including new tests) to detect more cases, by re-testing all specimens that had negative/discrepant antibody results on initial screening. FINDINGS The antibody-RNA algorithm identified 58 acute and 703 established HIV infection cases. 1(st)-generation (Vironostika) and 3(rd)-generation (Genetic Systems) immunoassays had 92 and 96 percent sensitivity, respectively. The Oraquick rapid test had clinical sensitivity of only 86 percent on oral fluid samples, but 92 percent on finger-stick blood. Newer 4(th)-generation, antigen-antibody combo rapid immunoassay (ARCHITECT) detected HIV in 87 percent of all the acute cases that had been missed by one of the previous screening assays. A point-of-care 4(th) generation antigen-antibody combo rapid test (Determine) detected about 54 percent of such acute cases. CONCLUSIONS Our study suggests that some rapid antibody blood tests will give similar case detection to laboratory antibody tests, but that oral fluid testing greatly reduces ability to detect HIV. New 4(th)-generation combo tests can detect the majority of acute infections detectable by HIV RNA but with rapid results. Using these tests as a primary screening assay in high-risk HIV testing programs could reduce or eliminate the need for HIV RNA testing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Detection of acute HIV infection: a field evaluation of the determine® HIV-1/2 Ag/Ab combo test.

BACKGROUND Most human immunodeficiency virus (HIV) point-of-care tests detect antibodies (Ab) but not p24 antigen (Ag) or RNA. In the absence of antibodies, p24 antigen and RNA typically indicate acute HIV infection. We conducted a field evaluation of the Determine® HIV-1/2 Ag/Ab Combo rapid test (Combo RT). METHODS The antigen portion of the Combo RT (for acute HIV infection) was compared wi...

متن کامل

The Diagnosis of HIV Infection in Infants and Children

It is estimated that the number of HIV infected children globally has increased from 1.6 million in 2001 to 3.3 million in 2012. The number of children below 15 years of age living with HIV has increased worldwide. Published data from recent studies confirmed dramatic survival benefit for infants started anti-retroviral therapy (ART) as early as possible after diagnosis of HI. Early confirmatio...

متن کامل

Performance of Risk-Based Criteria for Targeting Acute HIV Screening in San Francisco

BACKGROUND Federal guidelines now recommend supplemental HIV RNA testing for persons at high risk for acute HIV infection. However, many rapid HIV testing sites do not include HIV RNA or p24 antigen testing due to concerns about cost, the need for results follow-up, and the impact of expanded venipuncture on clinic flow. We developed criteria to identify patients in a municipal STD clinic in Sa...

متن کامل

Low Molecular Weight Heparin Overdose: A 10 Year Case Series

  Background: Low molecular weight heparin (LMWH) is used for the treatment and prevention of coagulative disorders. Few patients receiving therapeutic doses of LMWH develop major hemorrhage. Currently there are few reports in the literature on acute overdose on adults.  In this study, clinical profile, treatment and outcome of 21 patients who acutely overdosed enoxaparin are described. Method...

متن کامل

Accuracy and impact of a point-of-care rapid influenza test in young children with respiratory illnesses.

OBJECTIVE To determine whether a point-of-care rapid influenza test impacts the diagnostic evaluation and treatment of children with acute respiratory illnesses. DESIGN Randomized controlled trial. SETTING Pediatric emergency department and acute care clinic of a children's hospital. PARTICIPANTS Children aged younger than 5 years with fever or acute respiratory symptoms during 2 influenz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013