Two-photon LIF on the HIT-SI3 experiment: Absolute density and temperature measurements of deuterium neutrals.
نویسندگان
چکیده
Two-photon laser-induced fluorescence measurements were performed on the helicity injected torus (HIT-SI3) device to determine the density and temperature of the background neutral deuterium population. Measurements were taken in 2 ms long pulsed plasmas after the inductive helicity injectors were turned off. Attempts to measure neutrals during the main phase of the plasma were unsuccessful, likely due to the density of neutrals being below the detection threshold of the diagnostic. An unexpectedly low density of atomic deuterium was measured in the afterglow; roughly 100 times lower than the theoretical prediction of 1017 m-3. The neutral temperatures measured were on the order of 1 eV. Temporally and spatially resolved neutral density and temperature data are presented.
منابع مشابه
Optimization of confocal laser induced fluorescence in a plasma.
Laser Induced Fluorescence (LIF) provides measurements of flow speed, temperature, and density of ions or neutrals in a plasma. Traditionally, a LIF measurement requires two ports on a plasma device; one for laser injection and one for emission collection. Proper alignment of LIF optics is time consuming and sensitive to mechanical vibration. We describe a confocal configuration for LIF that re...
متن کاملContinuous wave cavity ring down spectroscopy measurements of velocity distribution functions of argon ions in a helicon plasma.
We report continuous wave cavity ring down spectroscopy (CW-CRDS) measurements of ion velocity distribution functions (VDFs) in low pressure argon helicon plasma (magnetic field strength of 600 G, T(e) ≈ 4 eV and n ≈ 5 × 10(11) cm(-3)). Laser induced fluorescence (LIF) is routinely used to measure VDFs of argon ions, argon neutrals, helium neutrals, and xenon ions in helicon sources. Here, we d...
متن کاملTwo photon absorption laser induced fluorescence measurements of neutral density in a helicon plasma
We have developed a new diagnostic based on two-photon absorption laser induced fluorescence (TALIF). We use a high intensity (5 MW/cm), narrow bandwidth (0.1 cm ) laser to probe the ground state of neutral hydrogen, deuterium and krypton with spatial resolution better than 0.2 cm, a time resolution of 10 ns, and a measurement cadence of 20 Hz. Here, we describe proof-of-principle measurements ...
متن کاملDiagnosing ions and neutrals via n=2 excited hydrogen atoms in plasmas with high electron density and low electron temperature.
Ion and neutral parameters are determined in the high electron density, magnetized, hydrogen plasma beam of an ITER divertor relevant plasma via measurements of the n=2 excited neutrals. Ion rotation velocity (up to 7 km/s) and temperature (2-3 eV~T_{e}) are obtained from analysis of Hα spectra measured close to the plasma source. The methodology for neutral density determination is explained w...
متن کاملPhoton Dosimetry Quality Audit of Radiotherapy Centers in Iran: SSDL's On-Site Visit Program During 2007-2017
Introduction: A dosimetric audit is a quality assurance process (QA) that allows the accuracy of dosimetric and geometric precision to accurately control the delivery of doses. They can be used to evaluate the accuracy of radiation delivery at different radiotherapy centers. Differences in prescriptive doses, depending on the severity of the differences, have potential conseque...
متن کاملذخیره در منابع من