A truly hybrid interventional MR/X-ray system: feasibility demonstration.
نویسندگان
چکیده
A system enabling both x-ray fluoroscopy and MRI in a single exam, without requiring patient repositioning, would be a powerful tool for image-guided interventions. We studied the technical issues related to acquisition of x-ray images inside an open MRI system (GE Signa SP). The system includes a flat-panel x-ray detector (GE Medical Systems) placed under the patient bed, a fixed-anode x-ray tube overhead with the anode-cathode axis aligned with the main magnetic field and a high-frequency x-ray generator (Lunar Corp.). New challenges investigated related to: 1) deflection and defocusing of the electron beam of the x-ray tube; 2) proper functioning of the flat panel; 3) effects on B0 field homogeneity; and 4) additional RF noise in the MR images. We have acquired high-quality x-ray and MR images without repositioning the object using our hybrid system, which demonstrates the feasibility of this new configuration. Further work is required to ensure that the highest possible image quality is achieved with both MR and x-ray modalities.
منابع مشابه
Switching on the lights for real-time multimodality tumor neuroimaging: The integrated positron-emission tomography/MR imaging system.
A recent report of the feasibility of simultaneous PET/MR imaging of the healthy human brain has sparked excitement in the field of neuroimaging because of its potential influence and utility in clinical neuroscience research. The aim of this communication is to discuss the benefits and current drawbacks of the hybrid imaging system and to highlight some perspectives of the new technique for br...
متن کاملInterventional MRI-guided local delivery of agents into swine bile duct walls using MR-compatible needle-integrated balloon catheter system.
The purpose of this study was to investigate the feasibility of interventional MRI-guided local agent delivery into pig common bile duct (CBD) walls using a newly designed MR-compatible, needle-integrated balloon catheter system. We first designed a needle-integrated balloon catheter system that comprised of a 22 G MR-compatible Chiba biopsy needle and a conventional 12 mm × 2 cm balloon cathet...
متن کاملMagnetic resonance-guided placement of atrial septal closure device in animal model of patent foramen ovale.
BACKGROUND Percutaneous closure of the patent foramen ovale (PFO) is usually performed under x-ray in combination with ultrasound guidance. We tested the feasibility of applying magnetic resonance (MR) guidance for percutaneous closure of PFO in an animal model, thus avoiding the disadvantage of ionizing radiation. METHODS AND RESULTS Real-time MRI with radial or spiral k-space filling (15 fr...
متن کاملAn Optical and Electromagnetic Hybrid Tracking System for MR Image Guided Interventional Procedures
INTRODUCTION In MR guided interventional procedures, image planes are required to include the needle path accurately. For the purpose, an optical or electromagnetic tracking system has been used. The optical tracking system precisely works in the strong magnetic fields, but line of sight must be maintained. Surgical procedure and instruments easily obstruct the light path and applicable angles ...
متن کاملOPTIMAL HYBRID BASE ISOLATION AND MR DAMPER
In this paper, optimal design of hybrid low damping base isolation and magnetorheological (MR) damper has been studied. Optimal hybrid base isolation system has been designed to minimize the maximum base drift of low damping base isolation system where for solving the optimization problem, genetic algorithm (GA) has been used. In design procedure the maximum acceleration of the structure has ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of magnetic resonance imaging : JMRI
دوره 13 2 شماره
صفحات -
تاریخ انتشار 2001