Root Cause Analysis (RCA) of Prolonged Laboratory Turnaround Time in a Tertiary Care Set up.

نویسنده

  • Kalyan Khan
چکیده

INTRODUCTION Among the multitude of daily administrative problems which are faced by the modern hospitals today, prolonged Turnaround Time (TAT) of laboratory investigations is a crucial one, which affects patient care as well as patient satisfaction adversely. AIMS AND OBJECTIVES The specific objectives were to observe the TAT of common laboratory investigations, to identify cause of increased turnaround time and to formulate action plans to rectify increased TAT. METHODOLOGY An observational, RCA study was performed on 100 randomly selected patients. A separate group of 50 patients were assisted to get their investigations done and to reduce the time intervals without actively interfering with the steps. The results which were obtained were accepted as standards. Root cause analysis of the delays which were detected in TAT was done. Time intervals of TAT in the two groups were compared by 2 tailed t-tests done for equality of means. Result and Analysis: All time intervals were high in the study group and they were found to be statistically significant (p<0.05) within a 95% confidence interval of the difference. The maximum time which was needed in the control group was within the interval between the prescription of the investigation by the doctor and writing of the requisition by the Out-patient Department (OPD) staff. For the study population, it was the interval between the writing of the requisition by the OPD staff and the reaching of the patient at the central Laboratory. The standard deviation (27.665) and range (102) were also exceptionally high for this interval in the study group. CONCLUSION This study revealed that easy to implement administrative steps would help in reducing the TAT significantly and in improving the quality of services of the central laboratory. These include the setting up of sample collection counters at the outpatient department (OPD) and inpatient department (IPD), employment of minor methods like printing the directions for reaching the laboratory on the OPD ticket, the start of a single prick policy, declaring central laboratory as a separate department and integration of the administrative control under one authority.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lean six sigma process improvement in specimen receiving to improve stat chemistry turnaround times

  Objective: As a consequence of stat turnaround times (TATs) chronically exceeding 60 minutes, our laboratory was facing pressure to divert limited resources toward the implementation of an emergency department satellite laboratory. Peer-reviewed literature in clinical laboratory quality assurance and improvement indicates that between 60-70% of errors occur at the pre-analytical level.  Thus...

متن کامل

Effect size of contributory factors on adverse events: an analysis of RCA series in a teaching hospital

BACKGROUND One of the most important concerns of health care systems in the world is the patient safety issues. Root Cause Analysis is a systematic process for identifying root causes and contributory factors of problems or events. The objective of this study is to review RCA reports to determine the effect size of contributory factors on adverse events through an organizational perspective. ...

متن کامل

System-wide learning from root cause analysis: a report from the New South Wales Root Cause Analysis Review Committee.

BACKGROUND Preventable errors are common in healthcare. Over the last decade, Root Cause Analysis (RCA) has become a key tool for healthcare services to investigate adverse events and try to prevent them from happening again. The purpose of this paper is to highlight the work of the New South Wales (NSW) RCA Review Committee. The benefits of correctly classifying, aggregating and disseminating ...

متن کامل

Monitoring of Turnaround time (TAT) in Biochemistry Laboratory of a tertiary care hospital in Punjab

Turnaround time (TAT) is commonly defined as the time from when a test is ordered until the result is reported which includes the preanalytical, analytical and post-analytical time. Increased attention to patient’s needs is demonstrated by efforts to improve the quality of the entire service provided, e. g reduction of laboratory turnaround time (TAT). The availability of the results from a lab...

متن کامل

The Evaluation of Error Types and Turnaround Time of Preanalytical Phase in Biochemistry and Hematology Laboratories

Background& Objective: Each laboratory should determine the type of errors and turnaround time (TAT), especially in the preanalytical phase to report quality and timeliness of the test results. The current study aimed at investigating the common causes of preanalytical errors in biochemistry and hematology laboratories and evaluating the preanalytical ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical and diagnostic research : JCDR

دوره 8 4  شماره 

صفحات  -

تاریخ انتشار 2014