Real-time slit scanning microscopy in the meridional plane.

نویسندگان

  • Edward J Botcherby
  • Martin J Booth
  • Rimas Juskaitis
  • Tony Wilson
چکیده

The standard microscope architecture around which confocal microscopes are built imposes fundamental restrictions on the speed with which images (three-dimensional data sets) can be obtained. Commercially available slit scanning confocal microscopes are able to produce optically sectioned images at frame rates well in excess of 100 Hz. However only the focal (x-y) plane can be imaged at this speed. To image a volume specimen it is necessary to physically change the distance between the objective lens and the specimen. This refocusing process is often necessarily slow and represents a bottleneck to the speed of image acquisition. We describe the construction of a slit scanning confocal microscope based on what we know to be a novel microscope architecture, which permits images of other planes and, particular, the meridional (x-z) plane to be acquired in real time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Inviscid Compressible Flow in Meridional Plane of an Axial Flow Compressor

In this paper it is attempted to investigate the behavior of an inviscid flow in the meridional plane of an axial flow compressor. For this purpose the 3-D unsteady Euler equations in cylindrical coordinate are averaged in tangential direction. Therefore, the equations are reduced to a 2-D system. By averaging the tangential component of momentum equation, a blade force will result. Axial and r...

متن کامل

Inviscid Compressible Flow in Meridional Plane of an Axial Flow Compressor

In this paper it is attempted to investigate the behavior of an inviscid flow in the meridional plane of an axial flow compressor. For this purpose the 3-D unsteady Euler equations in cylindrical coordinate are averaged in tangential direction. Therefore, the equations are reduced to a 2-D system. By averaging the tangential component of momentum equation, a blade force will result. Axial and r...

متن کامل

Revisiting the Conformation and Dynamics of DNA in Slitlike Confinement

We experimentally investigated the equilibrium conformation and dynamics of single DNA molecules in slitlike nanochannels. We measured the in-plane radius of gyration (R )), diffusivity (D), and longest relaxation time (τ) of λ-DNA (48.5 kbp) as functions of the slit height using fluorescence microscopy. Our results show that the in-plane radius of gyration increases monotonically with decreasi...

متن کامل

Method and Its Trial Instrumentation for High Speed and Continuous 3-D Measurement

This systcm is based on slit-ray projcction mcthod. The remarkable featurcs of this systcm -high speed and continuous rneasuremcnt -mainly comes from its image plane constructed by PSD array which is horizontally non-divided and linear, whereas vertically dividcd in numbers. Each row PSD element is attached to respective analog signal proccssor, A/D converter and mcmory clcmcnt. By the virtue o...

متن کامل

Evaluation of Microscopy Sensitivity, Specificity in Detection of P. falciparum and P. vivax, Using Monoplex real-time PCR, Gezira, Sudan

Background: Malaria is still account for 200 million cases annually. Microscopy is the gold standard technique for malaria parasites detection. PCR-based techniques can detect malaria infections with high sensitivity. The study aimed to evaluate the sensitivity of microscopy technique in the detection of P. falciparum and P. vivax, using monoplex real-time PCR, Gezira State, Central Sudan. Met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Optics letters

دوره 34 10  شماره 

صفحات  -

تاریخ انتشار 2009