Impact of periodic breathing on measurement of oxygen uptake and respiratory exchange ratio during cardiopulmonary exercise testing.

نویسندگان

  • Darrel P Francis
  • L Ceri Davies
  • Keith Willson
  • Roland Wensel
  • Piotr Ponikowski
  • Andrew J S Coats
  • Massimo Piepoli
چکیده

Metabolic exercise testing is valuable in patients with chronic heart failure (CHF), but periodic breathing may confound the measurements. We aimed to examine the effects of periodic breathing on the measurement of oxygen uptake ( V*O(2)) and respiratory exchange ratio (RER). First, we measured the effects of different averaging procedures on peak V*O(2) and RER values in 122 patients with CHF undergoing cardiopulmonary exercise testing. Secondly, we studied the effects of periodic breathing on V*O2) and RER in healthy volunteers performing computer-guided periodic breathing. Thirdly, we used a Fourier analysis to study the effects of periodic breathing on gas exchange measurements. The first part of the study showed that 1 min moving window gave a mean peak V*O(2) of 13.8 ml.min(-1).kg(-1) for the CHF patients. A 15 s window gave significantly higher values. The difference averaged 1.0 ml.min(-1).kg(-1) ( P <0.0001), but varied widely: 41% of subjects showed a difference greater than 1.0 ml.min(-1).kg(-1). RER values were also higher by an average of 0.09 ( P <0.0001); in 20% of subjects the difference was greater than 0.10. In the second part of the study, we found artefactual elevations of peak V*O(2) (without averaging) of 2.9 ml.min(-1).kg(-1) ( P <0.01) and of peak RER of 0.13 ( P <0.001), which were still significant when 30 s averaging was applied [delta(peak V*O(2))=1.8 ml.min(-1).kg(-1), P <0.01; deltaRER=0.08, P <0.001]. The third, theoretical, part of the study showed that values of carbon dioxide output and V*O(2) oscillate with different phases and amplitudes, resulting in oscillations in their ratio, RER. Averaging over 15 s or 30 s can be expected to give only 10% or 36% attenuation respectively. Thus periodic breathing causes variable artefactual elevations of measured peak V*O(2) and RER, which can be attenuated by using longer averaging periods. Clinical reports and research publications describing peak V*O(2) in CHF should be accompanied by details of the averaging technique used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Do unapposed stent struts endothelialise? In vivo demonstration with optical coherence tomography.

1 Piepoli MF, Ponikowski PP, Volterrani M, et al. Aetiology and pathophysiological implications of oscillatory ventilation at rest and during exercise in chronic heart failure. Do Cheyne and Stokes have an important message for modern-day patients with heart failure? Eur Heart J 1999;20:946–53. 2 Vangesselen S, Weymans M, Mertens L, et al. A Java software for calculating mean breath-by-breath v...

متن کامل

Cardiopulmonary exercise testing following hay exposure challenge in farmer's lung.

In patients experiencing an acute episode of hypersensitivity pneumonitis (HP), the alveoli and interstitium show a marked inflammation. The effects of this infiltration with effector cells on gas exchange and the cardiopulmonary system are not well characterized, and there are no data regarding cardiopulmonary exercise testing during hypersensitivity pneumonitis. The aim of this study was to g...

متن کامل

Ventilatory Abnormalities During Exercise in Heart Failure: A Mini Review

Heart Failure (HF) is a significant health care concern with in both the United States and Europe. While there are a number of mechanisms that lead to HF, a decline in the response to exercise is common amongst the various etiologies. Cardiopulmonary exercise testing (CPET) is a well established diagnostic and prognostic tool in the HF population. This exercise testing technique allows for the ...

متن کامل

New Parameters of Cardiopulmonary Exercise Testing in Patients with Chronic Heart Failure: Practical Applications

Cardiopulmonary exercise testing (CPX) has become the cornerstone of risk stratification for heart failure patients. Peak oxygen consumption (VO2) was the first CPX variable to demonstrate prognostic value and is still the most frequently analyzed variable in clinical practice. More recently, several investigations have shown that ventilatory efficiency, typically expressed as the minute ventil...

متن کامل

The prognostic value of cardiopulmonary exercise testing in idiopathic pulmonary fibrosis.

RATIONALE Idiopathic pulmonary fibrosis (IPF) is characterized by progressive dyspnea, impaired gas exchange, and ultimate mortality. OBJECTIVES To test the hypothesis that maximal oxygen uptake during cardiopulmonary exercise testing at baseline and with short-term longitudinal measures would predict mortality in patients with idiopathic pulmonary fibrosis. METHODS Data from 117 patients w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical science

دوره 103 6  شماره 

صفحات  -

تاریخ انتشار 2002