Simulation of passive ground-coupled cooling system for a house in hot humid climate
نویسنده
چکیده
Abstract The US government has set a target of reducing CO2 emissions by 20% below the 2005 targets by the year 2020. Literature review reveals that residential buildings contribute over 20% of the total emissions mainly used for space heating, cooling, water heating and lighting. In hot humid climates, the concern is mainly for cooling and hot water that account for over 50% of the total residential energy consumption in South Florida as pointed out by Fairey and Parker [1].
منابع مشابه
The Use of Housing System in the Management of Heat Stress in Poultry Production in Hot and Humid Climate: a Review
There is a gap between the population growth and protein supply in many tropical countries where per capita income is low and the majority of people consume less protein than a daily standard for recommended protein intake. Poultry egg production remains the fastest route to bridging the protein demand-supply gap in these regions. However, poultry are faced with heat stress in the tropics which...
متن کاملPotentials of Vernacular Climatic Solutions (VCS) in Energy Efficiency of Domestic Buildings in Hot and Humid Climate: The Case Study of Bushehr, Iran
This study aims to use vernacular climatic solutions (VCS) of traditional dwellings of Bushehr in common residential buildings of this city in southern Iran and answer to the question that “What is the effect of VCS in terms of energy consumption in these buildings?”. This research was conducted on two levels. At the first level, after selecting an existing model of common residential buildings...
متن کاملThe Study of Thermostat Impact on Energy Consumption in a Residential Building by Using TRNSYS
The present study investigates the effectiveness of thermostat control strategy in cooling energy consumption in residential buildings. To evaluate the energy consumption, two scenarios including a residential zone with and without the thermostat control system are assumed. The TRNSYS software provides an efficient numerical tool to model and evaluate a cooling system. Furthermore, since solar-...
متن کاملApplication of Radiant Cooling in Different Climates: Assessment of Office Buildings through Simulation
The energy performance of radiant slab cooling relative to conventional air systems to be clarified for climates from cold and dry to very hot and humid. EnergyPlus simulations were used to compare the energy performance of 1) radiant slab cooling combined with a dedicated outdoor air system and 2) a variable air volume system. Simulation results show that the radiant slab system provided 10% t...
متن کاملComparative assessment of vernacular passive cooling techniques for improving indoor thermal comfort of modern terraced houses in hot¬タモhumid climate of Malaysia
The main objectives of this study were to investigate vernacular passive cooling techniques and their potential application for improving indoor thermal comfort of naturally ventilated, modern brick terraced houses in Malaysia. Field measurement was conducted in two traditional timber Malay houses and two traditional masonry Chinese shophouses to examine their indoor thermal environments. The r...