Toxicity of cobalt-chromium nanoparticles released from a resurfacing hip implant and cobalt ions on primary human lymphocytes in vitro.
نویسندگان
چکیده
Adverse tissue responses to prostheses wear particles and released ions are important contributors to hip implant failure. In implant-related adverse reactions T-lymphocytes play a prominent role in sustaining the chronic inflammatory response. To further understand the involvement of lymphocytes in metal-on-metal (MoM) implant failure, primary human lymphocytes were isolated and treated with cobalt-chromium (Co-Cr) wear debris and Co ions, individually, and in combination, for 24, 48 and 120 h. There was a significant increase in cell number where debris was present, as measured by the Neutral Red assay. Interleukin-6 (IL-6), interferon-γ (IFN-γ) and tumour necrosis factor-α (TNF-α) secretion levels significantly decreased in the presence of metal particles, as measured by ELISA. Interleukin-2 (IL-2) secretion levels were significantly decreased by both debris and Co ions. Flow cytometry analysis showed that the metal nanoparticles induced a significant increase in apoptosis after 48-h exposure. This investigation showed that prolonged exposure (120 h) to metal debris induces lymphocyte proliferation, suggesting that activation of resting lymphocytes may have occurred. Although cytokine production was affected mainly by metal debris, cobalt toxicity may also modulate IL-2 secretion, and even Co ion concentrations below the MHRA guideline levels (7 ppb) may contribute to the impairment of immune regulation in vivo in patients with MoM implants.
منابع مشابه
Effects of CoCr metal wear debris generated from metal-on-metal hip implants and Co ions on human monocyte-like U937 cells.
Hip resurfacing with cobalt-chromium (CoCr) alloy was developed as a surgical alternative to total hip replacement. However, the biological effects of nanoparticles generated by wear at the metal-on-metal articulating surfaces has limited the success of such implants. The aim of this study was to investigate the effects of the combined exposure to CoCr nanoparticles and cobalt ions released fro...
متن کاملChromium and cobalt ion release following the Durom high carbon content, forged metal-on-metal surface replacement of the hip.
We evaluated the concentrations of chromium and cobalt ions in blood after metal-on-metal surface replacement arthroplasty using a wrought-forged, high carbon content chromium-cobalt alloy implant in 64 patients. At one year, mean whole blood ion levels were 1.61 microg/L (0.4 to 5.5) for chromium and 0.67 microg/L (0.23 to 2.09) for cobalt. The pre-operative ion levels, component size, female ...
متن کاملMetal ion levels and lymphocyte counts: ASR hip resurfacing prosthesis vs. standard THA
BACKGROUND AND PURPOSE Wear particles from metal-on-metal arthroplasties are under suspicion for adverse effects both locally and systemically, and the DePuy ASR Hip Resurfacing System (RHA) has above-average failure rates. We compared lymphocyte counts in RHA and total hip arthroplasty (THA) and investigated whether cobalt and chromium ions affected the lymphocyte counts. METHOD In a randomi...
متن کاملHip resurfacing versus metal-on-metal total hip arthroplasty - are metal ion levels different?
A systematic review and meta-analysis of trials comparing hip resurfacing to metal-on-metal total hip arthroplasty was conducted to determine if there is a difference in serum metal ion levels in patients receiving these implants. EMBASE and MEDLINE databases were searched from inception to December 2010 for all trials involving the use of these devices. Eligibility for inclusion in the review ...
متن کاملEarly failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: A consequence of excess wear.
Early failure associated with adverse reactions to metal debris is an emerging problem after hip resurfacing but the exact mechanism is unclear. We analysed our entire series of 660 metal-on-metal resurfacings (Articular Surface Replacement (ASR) and Birmingham Hip Resurfacing (BHR)) and large-bearing ASR total hip replacements, to establish associations with metal debris-related failures. Clin...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied toxicology : JAT
دوره 35 6 شماره
صفحات -
تاریخ انتشار 2015