INSTITUTE Instrument Science Report STIS 2009 - 02 STIS CCD Performance after SM 4 : Read Noise , Dark Current , Hot Pixel Annealing , CTE , Gain , and Spectroscopic Sensitivity
نویسندگان
چکیده
We describe the overall performance of the STIS CCD after HST Servicing Mission #4 and the associated updates to calibration reference files. Most aspects of CCD performance are found to be fairly consistent with extrapolations of the trends seen prior to the failure of STIS in August 2004. The CCD gain value for the CCDGAIN = 4 setting has been redetermined using net count ratios of standard star spectra taken in the CCDGAIN = 1 and CCDGAIN = 4 settings, resulting in a gain value of 4.016 ± 0.003 e/DN, which is 0.5% lower than the value used for the calibration of archival STIS CCD data taken before August 2004. Finally, we identify two independent indications of a temperature dependence of the Charge Transfer Efficiency (CTE). However, more calibration data are needed to verify the significance of this effect and, if verified, to calibrate it as a function of CCD housing temperature (as a proxy for CCD chip temperature). This option will be reassessed later during the Cycle 17 calibration program.
منابع مشابه
A new CTE Correction Algorithm for Point Source Spectroscopy with the STIS CCD : Correcting for charge trap filling by the ‘ red halo ’ of the CCD Point Spread Function redward of 8000 Å
The CTE-related loss for spectrophotometry of point sources with the STIS CCD is parametrized in terms of dependencies on the signal level of the source spectrum within the extraction box, the background level, and the signal in the point spread function located between the standard extraction box and the read-out amplifier. Primary constraints on the CTE correction algorithm are provided by es...
متن کاملAn Algorithm for Correcting CTE Loss in Spectrophotometry of Point Sources with the STIS CCD
The correction for the change in sensitivity with time for the STIS CCD modes is complicated by the gradual loss of charge transfer efficiency (CTE) of the CCD. The amount of this CTE loss depends on time in orbit, the location on the CCD chip with respect to the readout amplifier, the stellar signal strength, and the background level. Primary constraints on our correction algorithm are provide...
متن کاملar X iv : a st ro - p h / 96 11 10 9 v 1 1 4 N ov 1 99 6 Submitted to PASP Imaging With STIS : Astronomy at V = 30
In February, 1997, the second Space Shuttle servicing mission to the Hubble Observatory will install the Space Telescope Imaging Spectrograph (STIS). This new instrument will greatly enhance the spectroscopic capabilities of the Hubble Space Telescope by providing a longslit format and CCD detector technology. STIS can also be used as an imager, providing an alternative to the Wide Field Planet...
متن کاملSTIS Calibration Enhancement: Wavelength Calibration and CTI
The Instrument Physical Modeling Group in the Space Telescope European Co-ordinating Facility has undertaken to examine aspects of STIS calibration and develop physical model based solutions where appropriate. Here we discuss two such aspects and the status of the model based solutions. The first concerns the derivation of dispersion solutions for the echelle spectroscopy modes. The second corr...
متن کاملUpdate on the STIS CCD CTE Performance
STIS has been operating without major changes in its performance since the release of the STIS Instrument Handbook (IHB) version 4.1. This update provides the latest information regarding STIS performance and policies which are relevant to the preparation of Cycle 10 Phase II proposals. The items presented here may also be found on the STIS web page at http://www.stsci.edu/instruments/stis. As ...
متن کامل