Predicting tissue distribution and partitioning in terminal sire sheep using x-ray computed tomography.
نویسندگان
چکیده
The utility of x-ray computed tomography (CT) scanning in predicting carcass tissue distribution and fat partitioning in vivo in terminal sire sheep was examined using data from 160 lambs representing combinations of 3 breeds (Charollais, Suffolk, and Texel), 3 genetic lines, and both sexes. One-fifth of the lambs were slaughtered at each of 14, 18, and 22 wk of age, and the remaining two-fifths at 26 wk of age. The left side of each carcass was dissected into 8 joints with each joint dissected into fat (intermuscular and subcutaneous), lean, and bone. Chemical fat content of the LM was measured. Tissue distribution was described by proportions of total carcass tissue and lean weight contained within the leg, loin, and shoulder regions of the carcass and within the higher-priced joints. Fat partitioning variables included proportion of total carcass fat contained in the subcutaneous depot and intramuscular fat content of the LM. Before slaughter, all lambs were CT scanned at 7 anatomical positions (ischium, midshaft of femur, hip, second and fifth lumbar vertebrae, sixth and eighth thoracic vertebrae). Areas of fat, lean, and bone (mm(2)) and average fat and lean density (Hounsfield units) were measured from each cross-sectional scan. Areas of intermuscular and subcutaneous fat were measured on 2 scans (ischium and eighth thoracic vertebra). Intramuscular fat content was predicted with moderate accuracy (R(2) = 56.6) using information from only 2 CT scans. Four measures of carcass tissue distribution were predicted with moderate to high accuracy: the proportion of total carcass (R(2) = 54.7) and lean (R(2) = 46.2) weight contained in the higher-priced joints and the proportion of total carcass (R(2) = 77.7) and lean (R(2) = 55.0) weight in the leg region. Including BW in the predictions did not improve their accuracy (P > 0.05). Although breed-line-sex combination significantly affected fit of the regression for some tissue distribution variables, the values predicted were changed only trivially. Within terminal sire type animals, using a common set of prediction equations is justified. Tissue distribution and fat partitioning affect eating satisfaction and efficiency of production and processing; therefore, including such carcass quality measures in selection programs is increasingly important, and CT scanning appears to provide opportunities to do so.
منابع مشابه
Predicting carcass composition of terminal sire sheep using X-ray computed tomography
The best means to utilize X-ray computed tomography (CT) and ultrasound to predict carcass lean, fat and bone weights in vivo in terminal sire sheep were tested. Data on 160 lambs from three breeds were considered: 50 Suffolk males, 50 Suffolk females, 40 Texel males and 20 Charollais males. One-fifth of the lambs within each breed and sex group were slaughtered at each of 14, 18 and 22 weeks o...
متن کاملAn iterative method to estimate x-ray attenuation coefficients in computed tomography
Introduction: The basis of image formation in Computed Tomography (CT) lies in the x-ray linear attenuation coefficient of the scanned material. Compton scattering and photoelectric effect are the dominant interactions of the x-ray photons with the subject, in the range of diagnostic radiology. These two coefficients are important in tissue characterization by Dual-Energy CT (D...
متن کاملAssessment of X-Ray Crosstalk in a Computed Tomography Scanner with Small Detector Elements Using Monte Carlo Method
Introduction: Crosstalk is a leakage of X-ray or light produced in a matrix of X-ray detectors or array of photodiodes in one element to other elements affecting on image contrast and spatial resolution. In this study, we assessed X-ray crosstalk in a computed tomography (CT) scanner with small detector elements to estimate the effect of various parameters such as X-ray tube voltage, detector e...
متن کاملPatient doses from X-ray computed tomography examinations by a single-array detector unit: Axial versus spiral mode
Background: X-ray computed tomography (CT) examinations deliver a significant amount of radiation doses to patients comparing to conventional radiography examinations. The objective of the current study was to analyze and investigate the average patient received dose from axial and spiral CT exams in a medical imaging center. Material and Methods: In this study, the patient imaging tec...
متن کاملImpact of Photon Spectra on the Sensitivity of Polymer Gel Dosimetry by X-Ray Computed Tomography
Introduction: The purpose of the current study was to investigate the effect of X-ray spectra on the sensitivity of a polymer gel dosimeter imaged with a conventional computed tomography (CT) scanner. Material and Methods: The whole process of CT imaging of an irradiated polymer gel was simulated by MCNPX Monte Carlo (MC) code. The imaging of polyacrylamide gel was accomplished by means of a co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of animal science
دوره 87 1 شماره
صفحات -
تاریخ انتشار 2009