Influence of age on measured anatomical and physiological interpupillary distance (far and near), and near heterophoria, in Arab males
نویسندگان
چکیده
PURPOSE To compare the effects of age and near phoria on interpupillary distance measured at far (FIPD) and near (NIPD) using the Viktorin's and pupillometer (PD-5) methods. METHODS Interpupillary distance (IPD) by Viktorin's method and the corneal reflex pupillometer (PD-5) method, as well as near heterophoria by the Saladin near point card, were each obtained on 133 randomly selected normal subjects aged 20-67 years. Comparison within and between techniques, influence of age on IPD, and near heterophoria were assessed. RESULTS The mean FIPD varied significantly from the NIPD (P < 0.001 for both methods). Overall, FIPD ranged from 56-73 mm, and NIPD ranged from 50-70 mm. For FIPDs of 55 mm, 63 mm, and 71 mm, the corresponding NIPDs were less by 3.9 mm, 4.4 mm, and 5.0 mm, respectively, which were measured by Viktorin's method, and 4.0 mm, 4.6 mm, and 5.2 mm, respectively, measured by the PD-5 method. Between methods, the limits of agreement were: -3.9 mm and 3.2 mm (P > 0.05) for FIPD, and -3.1 mm and 2.9 mm (P > 0.05) for NIPD. Both IPDs varied significantly across age groups (P < 0.0001). Post hoc analysis revealed a significant variation (P < 0.01 in both techniques) only in the comparison between age groups 16-25 years and 41-67 years. The mean difference was -2.2 mm (-4.0 mm to -0.3 mm) and -2.8 mm (-4.7 mm to -1.0 mm) for Viktorin's method for FIPD and NIPD, respectively. For PD-5, the corresponding values were -1.3 mm (-3.2 mm to 0.4 mm) and -1.7 mm (-4.1 to -0.5 mm). Also, the near phoria differed significantly (P < 0.0001) across age groups and correlated positively with age (r(2) = 0.27, P < 0.0001) and NIPD (r(2) > 0.04; P < 0.03, both techniques). CONCLUSION The difference between FIPD and NIPD (about 4.4 mm in Arab males) was observed independent of the technique used. The Viktorin's and the PD-5 methods of IPD assessment resulted in similar values, and therefore, could be interchangeably used. However, caution is advised in cases of high power refractive corrections as the difference could vary from -4 mm to +3 mm (FIPD) and -3 mm to +3 mm (NIPD). Both IPDs have demonstrated an increase until the patients are in their early 40s, and a slight decrease has been observed thereafter. Age and NIPD were significantly associated with heterophoria in our subjects.
منابع مشابه
Interpupillary Distance Measurements among Students in the Kumasi Metropolis
Objective: The aim was to obtain interpupillary distance (IPD) measurements of students in the Kumasi Metropolis. The study will provide a database for manufacturers of spectacle frames and optical equipment with Ghana as the target population. The IPD is a crucial measure that needs to be considered before frames can be selected for patients who have been prescribed with spectacle corrections....
متن کاملVertical response of short and long span suspension bridges due to near and far fault earthquakeshttps://jeg.khu.ac.ir/files/site1/yekta_program/bb/tmpl_yekta/bb_end.gif
Many researches have been currently conducted on the effects of fault distance on structures revealing that their seismic response can differ according to their distance from the fault. Suspension bridges due to their long period and high flexibility can be more sensitive to this phenomenon, especially in vertical vibration. Since the engineers tend to use longer spans, the length factor should...
متن کاملComparison of Distance and Near Heterophoria by Two Clinical Methods
Introduction: In the evaluation of binocular function, the heterophoria is an essential measure. Historically, the relationship of the near phoric measure to the far phoria has been a critical finding in the diagnosis of convergence and divergence anomalies. There are a number of ways that the phorias can be measured. It is noted in the literature that different types of phoria measures are sta...
متن کاملSeismic behavior of RBS connections at near and far field earthquakes
Moment-resisting frames have extensive usage in earthquake-prone areas and high ability in energy dissipation.After the earthquake in Northridge 1994,Kobe 1995 fixed connections of steel structures have shown poor performance and generally they were caught brittle fracture of beam flange weld to the column.In order to remedy to avoid similar situations in future earthquakes,researchers introduc...
متن کاملThe effects of distance of attentional focus on accuracy, effectiveness, and perception of performance in volleyball jump serving of elite players
The aim of this study was to examine the effects of attentional focus on accuracy, effectiveness, and perception of the performance in volleyball jump serve of professional players. 12 professional volleyball players completed a 4 blocks of 8 trail (4 for accuracy, and 4 for effectiveness) of jump serve in four experimental conditions (Non-Instruction, Internal focus on hand movement, Near ...
متن کامل