Agreement of arterial sodium and arterial potassium levels with venous sodium and venous potassium in patients admitted to intensive care unit.

نویسندگان

  • Sunil Kumar Nanda
  • Lopamudra Ray
  • Asha Dinakaran
چکیده

INTRODUCTION Electrolyte abnormalities are one of the common causes of morbidity and mortality in critically ill patients. The turnaround time for electrolyte reporting should be as low as possible. Electrolytes are measured conventionally in serum obtained from venous blood by electrolyte analyser which takes 20 to 30 min. Point of care analysers are now available where in electrolytes can be measured in arterial blood within 5 min. This study was done to study the agreement of arterial sodium and arterial potassium with venous sodium and venous potassium levels. MATERIALS AND METHODS Venous sodium and venous potassium levels and arterial sodium and arterial potassium levels were analysed on 206 patient samples admitted to Intensive Care Unit (ICU). The venous values were compared with the arterial values for correlation. Venous sodium was compared with arterial sodium by spearman correlation. Venous potassium was compared with arterial potassium by pearson correlation. RESULTS The mean value of arterial sodium was 134 and venous sodium was 137. The mean value of arterial potassium was 3.6 and venous potassium was 4.1. The correlation coefficient obtained for sodium was 0.787 and correlation coefficient obtained for potassium was 0.701. There was positive correlation of arterial sodium and arterial potassium with venous sodium and venous potassium indicating agreement between the parameters. CONCLUSION Arterial sodium and arterial potassium can be used instead of venous sodium and venous potassium levels in management of critically ill patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه نتایج آزمایشات بیوشیمیایی و هماتولوژیک خون در دو روش خونگیری معمول و خونگیری از کاتتر ورید محیطی

Background and purpose: Some patients need to repeat certain tests. However, despite a peripheral vein catheter in the patients usually phlebotomy is done. This study examined the biochemical and hematological test results of the two methods of usual blood sampling and blood sampling through peripheral vein catheter. Materials and methods: A case-control study was carried out in 96 patients ...

متن کامل

Comparison of the point-of-care blood gas analyzer versus the laboratory auto-analyzer for the measurement of electrolytes

BACKGROUND Electrolyte values are measured both by arterial blood gas (ABG) analyzers and central laboratory auto-analyzers (AA), but a significant time gap exists between the availability of both these results, with the ABG giving faster results than the AA. The authors hypothesized that there is no difference between the results obtained after measurement of electrolytes by the blood gas and ...

متن کامل

Agreement between central venous and arterial blood gas measurements in the intensive care unit.

BACKGROUND AND OBJECTIVES Venous blood gas (VBG) analysis is a safer procedure than arterial blood gas (ABG) analysis and may be an alternative for determining acid-base status. The objective of this study was to examine the agreement between ABG and central VBG samples for all commonly used parameters in a medical intensive care unit (ICU) population. DESIGN, SETTING, PARTICIPANTS, & MEASURE...

متن کامل

Inter-instrumental comparison for the measurement of electrolytes in patients admitted to the intensive care unit

OBJECTIVE To investigate whether benchtop auto-analyzers (AAs) and arterial blood gas (ABG) analyzers, for measuring electrolyte levels of patients admitted to intensive care units (ICU), are equal and whether they can be used interchangeably. MATERIALS AND METHOD This study was conducted on 98 patients admitted to the ICU of the Institute of Medicine, Kathmandu, Nepal between 15 October and ...

متن کامل

Comparison of different methods for measurement of electrolytes in patients admitted to the intensive care unit

OBJECTIVES To investigate whether electrolyte levels measured by using blood gas analyzers (ABG) and auto-analyzers (AA) are equivalent and can be used interchangeably. METHODS This observational prospective study was conducted in 100 patients admitted to the Intensive Care Unit, Adnan Menderes University School of Medicine, Aydin, Turkey, between March and August 2014. Samples for both AA an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical and diagnostic research : JCDR

دوره 9 2  شماره 

صفحات  -

تاریخ انتشار 2015