Development of Low Frequency Pulsed NQR/NMR Spectrometer

نویسندگان

  • V. G Ravindranath
  • Preeti Hemnani
چکیده

An FPGA based NQR spectrometer has been designed for detection of N nuclei. The digital circuits required for NQR spectrometer i.e Pulse Programmer, DDS, digital receiver have been built inside FPGA. Combining FPGA chip with analog components, NQR spectrometer has been developed. N from NaNO2 is observed using same spectrometer. By adding a permanent magnet of uniform field NMR signal of proton as well as deuterium was also observed. Development of Low Frequency Pulsed NQR/NMR Spectrometer © 2016 Global Journals Inc. (US) G lo ba l J o ur na l of R es ea rc he s in E ng in ee ri ng ( ) V ol 13 Y e a r 20 16 F um e X V I I ss ue II V er si on I Preeti Hemnani , A. K.Rajarajan σ , Gopal Joshi, ρ & S. V. G Ravindranath Ѡ AbstractAn FPGA based NQR spectrometer has been An FPGA based NQR spectrometer has been designed for detection of N nuclei. The digital circuits required for NQR spectrometer i.e Pulse Programmer, DDS, digital receiver have been built inside FPGA. Combining FPGA chip with analog components, NQR spectrometer has been developed. N from NaNO2 is observed using same spectrometer. By adding a permanent magnet of uniform field NMR signal of proton as well as deuterium was also observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SQUID detected NMR and NQR

Ž . The dc Superconducting QUantum Interference Device SQUID is a sensitive detector of magnetic flux, with a typical flux noise of the order 1 mF Hz at liquid helium temperatures. Here F s"r2 e is the flux quantum. In our NMR or 0 0 NQR spectrometer, a niobium wire coil wrapped around the sample is coupled to a thin film superconducting coil deposited on the SQUID to form a flux transformer. W...

متن کامل

A Pulsed Spectrometer Designed for Feedback NQR

A pulsed NQR spectrometer specifically designed to facilitate real-time tuning of pulse sequence parameters is described. A modular approach based on the interconnection of several rack-mounted blocks provides easy access to all spectrometer signals and simplifies the task of modifying the spectrometer design. We also present experimental data that demonstrates the ability of the spectrometer t...

متن کامل

Multi-photon resonances in pure multiple-pulse NQR

We have observed multi-photon resonances in a system with a spin 3/2 irradiated simultaneously by a multiple pulse radiofrequency sequence and a low frequency field swept in the range 0-80 kHz. The used excitation scheme allowed us to measure the effective field of the radiofrequency sequence. A peculiarity of this scheme is that the intensity of the resonance lines decreases slowly with the mo...

متن کامل

NQR Studies of Atomic Arrangements

A very high sensitivity continuous wave NQR spectrometer was developed to detect pure NQR transitions at low frequencies (down to 200 kHz). A signal-to-noise ratio of more than 100 to 1 has been achieved at about 1.36 MHz for crystalline B 2 0 3 . Two large n B responses have been found in vitreous B 2 0 3 (NMR detected only one site) with linewidths of less than 30 kHz. A1 NQR spectra were obt...

متن کامل

Zero field NMR and NQR with selective pulses and indirect detection

Zero field NMR and NQR spectra are obtained by the application of dc magnetic field pulses to a demagnetized sample. Pulsed dc fields allow for selective excitation of isotopic species and provide a means for coherent manipulation of the spin system in zero field. Using these selective pulses and level crossing techniques, indirect detection of a quadrupolar nucleus may be accomplished via prot...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016