BACKGROUND We would like to investigate the if IMRT produced better target coverage and dose sparing to adjacent normal structures as compared with 3-dimensional conformal radiotherapy (3DCRT) and lateral opposing fields (LOF) for patients with Graves' ophthalmopathy treated with retro-orbital irradiation. METHODS Ten consecutive patients diagnosed with Graves' ophthalmopathy were prospectively recruited into this study. An individual IMRT, 3DCRT and LOF plan was created for each patient. Conformity index (CI), homogeneity index (HI) and other dosimetric parameters of the targets and organs-at-risk (OAR) generated by IMRT were compared with the other two techniques. RESULTS Mann-Whitney U test demonstrated that CI generated by IMRT was superior to that produced by 3DCRT and LOF (p=0.005 for both respectively). Similarly HI with IMRT was proven better than 3DCRT (p=0.007) and LOF (p=0.005). IMRT gave rise to better dose sparing to some OARs including globes, lenses and optic nerves as compared with 3DCRT but not with LOF. CONCLUSIONS IMRT, as compared with 3DCRT and LOF, was found to have a better target coverage, conformity and homogeneity and dose sparing to some surrounding structures, despite a slight increase but clinically negligible dose to other structures. Dosimetrically it might be a preferred treatment technique and a longer follow up is warranted to establish its role in routine clinical use.
منابع مشابه
Vulvar Cancer: Dosimetric Comparison of Advanced 3D Conformal Radiation Therapy Technique with Anteroposterior and Posteroanterior Irradiation Techniques
Introduction: The commonly used technique of radiation therapy for vulvar cancer consists of anteroposterior (AP) and posteroanterior (PA) fields. This is the first study that reports the dosimetric comparison between the AP-PA techniques and the new 3D advanced conformal technique (3D-ACT) based on the multiplicity of treatment fields in patients with squamous cell ca...
متن کاملDosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions
Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...
متن کاملComparison of two radiation techniques in breast boost delivery
Introduction: In the treatment of breast cancer, breast conserving surgery (BCS) and whole breast irradiation is a usual technique. The influence of lumpectomy boost following breast radiotherapy is apparent, but there are different delivery methods. This work intended to compare the dosimetric parameters of electron beams and photon beams for boosting irradiation in breast can...
متن کاملDosimetric Comparison of 3D Tangential Radiotherapy of Post-Lumpectomy Breast at Two Different Energies
Introduction: Radiation therapy following breast conserving surgery is one of the most common procedures performed in any radiation oncology department. A tangential parallel-opposed pair is almost always the technique of choice for this purpose. This technique is often performed based on 3D treatment planning. The aim of this study was to compare 3D treatment planning for two different energie...
متن کاملRetinal microvascular abnormalities in patients treated with external radiation for graves ophthalmopathy.
BACKGROUND A prospective study was conducted to determine if external ionizing radiation could favorably influence the orbital manifestations of Graves ophthalmopathy. Diabetes and untreated systemic hypertension were exclusion criteria. Radiation was directed to the orbits of 42 affected patients using 0.2 rad (20 Gy) delivered in 10 doses of 0.02 rad (2 Gy). Patients were periodically examine...