BACKGROUND Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we examined the accuracy of a novel method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus. METHODS We evaluated the theoretical impact of the measurement of the annulus diameter and area using the circumcircle of a triangle method on the decision to perform the procedure and choice of the prosthesis size. RESULTS Sixty-three consecutive patients were scheduled for TAVI. Mean age was 82 ± 4 years, and 25 patients (55.6 %) were female. Mean aortic annulus diameter was 20.3 ± 2.2 mm assessed by TEE on the mid-esophageal long-axis view and 23.9 ± 2.3 mm using CT (p < 0.001). There was a tendency for the TEE derived areas using the new method to be higher (p < 0.001). The TEE measurements were on average 42.33 mm(2) higher than the CT measurements without an evidence of a systematic over- or under-sizing (p = 1.00). Agreement between TEE and CT chosen valve sizes was good overall (kappa = 0.67 and weighted kappa = 0.71). For patients who turned out to have no AR, the two methods agreed in 84.6 % of patients. CONCLUSIONS CT remanis the gold standard in sizing of the aortic valve annulus. Nevertheless, sizing of the aortic valve annulus using TEE derived area may be helpful. The impact of integration of this method in the algorithm of aortic annulus sizing on the outcome of patients undergoing TAVI should be examined in future studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility of a new method using two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation; a case–control study

BACKGROUND Accurate preoperative assessment of the aortic annulus dimension is crucial for successful transcatheter aortic valve implantation (TAVI). In this study we validated a new method using two-dimensional transesophageal echocardiography (2D-TEE) for measurement of the aortic annulus prior to TAVI. METHODS We analysed 124 patients who underwent successful TAVI using a self-expandable p...

متن کامل

FDG-PET/CT for driveline infection in a patient with implantable left ventricular assist device.

can Society of Echocardiography Council for Intraoperative Echocardiography and the Society of Cardiovascular Anesthesiologists Task Force for Certification in Perioperative Transesophageal Echocardiography. J Am Soc Echocardiogr 1999;12: 884–900. 21. Wong DT, Bertaso AG, Liew GY, Thomson VS, Cunnington MS, Richardson JD et al. Relationship of aortic annular eccentricity and paravalvular regurg...

متن کامل

Preparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for improved valve sizing.

OBJECTIVES This study sought to evaluate whether supra-aortic angiography during preparatory balloon aortic valvuloplasty (BAV) improves valve sizing. BACKGROUND Current recommendations for valve size selection are based on annular measurements by transesophageal echocardiography and computed tomography, but paravalvular aortic regurgitation (PAR) is a frequent problem. METHODS Data of 270 ...

متن کامل

Three-dimensional echocardiography vs. computed tomography for transcatheter aortic valve replacement sizing.

AIMS The accuracy of transcatheter aortic valve replacement (TAVR) sizing using three-dimensional transoesophageal echocardiography (3D-TEE) compared with the gold-standard multi-slice computed tomography (MSCT) remains unclear. We compare aortic annulus measurements assessed using these two imaging modalities. METHODS AND RESULTS We performed a single-centre prospective cohort study, includi...

متن کامل

Aortic annular sizing for transcatheter aortic valve replacement using cross-sectional 3-dimensional transesophageal echocardiography.

OBJECTIVES This study compared cross-sectional three-dimensional (3D) transesophageal echocardiography (TEE) to two-dimensional (2D) TEE as methods for predicting aortic regurgitation after transcatheter aortic valve replacement (TAVR). BACKGROUND Data have shown that TAVR sizing using cross-sectional contrast computed tomography (CT) parameters is superior to 2D-TEE for the prediction of par...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BMC cardiovascular disorders

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015