The effect of laser pulse duration on ICP-MS signal intensity, elemental fractionation, and detection limits in fs-LA-ICP-MS
نویسندگان
چکیده
We investigated the role that pulse width has on the analytical capabilities of laser ablation-inductively coupled plasma-mass spectrometry (LA-ICP-MS), specifically in the range of 40 fs to 300 ps. Three main results of LA-ICP-MS were examined: signal intensity or sensitivity, elemental fractionation or that the ablated aerosol is representative of the bulk, and detection limits of various elements in the samples. The samples used for this experiment were NIST glass standards, dielectrics that exhibit different ablation properties compared to metal targets. Our results demonstrate that in the range of 40 fs to 1 ps, negligible differences occur in signal intensity, elemental ratios, and detection limits. The U/Pb and U/Th ratios, which were examined to ensure limited fractionation, give comparable results at all pulse widths investigated.
منابع مشابه
The influence of laser pulse duration and energy on ICP-MS signal intensity, elemental fractionation, and particle size distribution in NIR fs-LA-ICP-MS.
Laser parameters, typically wavelength, pulse width, irradiance, repetition rate, and pulse energy, are critical parameters which influence the laser ablation process and thereby influence the LA-ICP-MS signal. In recent times, femtosecond laser ablation has gained popularity owing to the reduction in fractionation related issues and improved analytical performance which can provide matrix-inde...
متن کاملThe effect of ultrafast laser wavelength on ablation properties and implications on sample introduction in inductively coupled plasma mass spectrometry.
We investigated the role of femtosecond (fs) laser wavelength on laser ablation (LA) and its relation to laser generated aerosol counts and particle distribution, inductively coupled plasma-mass spectrometry (ICP-MS) signal intensity, detection limits, and elemental fractionation. Four different NIST standard reference materials (610, 613, 615, and 616) were ablated using 400 nm and 800 nm fs l...
متن کاملLaser Ablation ICP-MS: particle size-dependent isotopic fractionation of copper in laser-generated aerosols
Laser induced isotopic fractionation Previous studies of laser ablation (LA) MC-ICP-MS analysis of Cu metal and sulphides showed reduced Cu/Cu ratios compared to solution nebulisation MC-ICP-MS of the same samples [1]. The fractionation of about 30ε (parts per 10,000) was reproduced repeatedly and observed, to a smaller degree, for Ag and Sb also. This deviation, which was attributed largely to...
متن کاملA new laser ablation system for quantitative analysis of solid samples with ICP-MS.
The laser ablation (LA) method is an effective technique for quantitative analysis. In the present work, a new LA system was developed for the high-sensitivity analysis of metal materials using inductively coupled plasma mass spectrometry (ICP-MS). This system consists of a high-frequency Q-switched laser and 2 scanning mirrors for scanning the ablation spot in an adequately large area of the s...
متن کاملIron isotope composition of particles produced by UV-femtosecond laser ablation of natural oxides, sulfides, and carbonates.
The need for femtosecond laser ablation (fs-LA) systems coupled to MC-ICP-MS to accurately perform in situ stable isotope analyses remains an open question, because of the lack of knowledge concerning ablation-related isotopic fractionation in this regime. We report the first iron isotope analysis of size-resolved, laser-induced particles of natural magnetite, siderite, pyrrhotite, and pyrite, ...
متن کامل