Unbiased Thermocouple Sensor Characterisation in Variable Flow Environments

نویسندگان

  • Peter C.F. Hung
  • Robert Kee
چکیده

A novel two-thermocouple sensor characterisation method for use in variable velocity flow environments is described. A difference equation method, recently developed by the authors for constant velocity flow applications, is extended to accommodate variable velocity flows using polynomial parameter fitting on a sliding data window. In particular, by using a novel difference equation formulation the invariance of time-constant ratio with respect to flow velocity is exploited to produce an efficient unbiased and consistent time-constant estimator. Monte-Carlo simulation studies show that the new algorithm outperforms alternatives in the literature without the restrictive requirement of a priori knowledge of thermocouple time constant ratios. Copyright © 2005 IFAC

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Identification Applied to Dual Sensor Transient Temperature Measurement ⋆

The harsh environment presented by engines, particularly in exhaust systems, necessitates the use of robust and therefore low bandwidth temperature sensors. Consequently, high frequencies are attenuated in the sensor output. A number of techniques for addressing this problem involve measurement of the gas temperature using two thermocouples with different time-constants and mathematical reconst...

متن کامل

On the stability and biasedness of the cross-relation blind thermocouple characterisation method

The in situ characterisation of thermocouple sensors is a challenging problem. Recently the authors introduced a novel blind characterisation technique based on the cross-relation method of blind identification that allows in situ characterisation of temperature measurement probes consisting of twothermocouple sensors with differing time constants. While the technique has a number of advantages...

متن کامل

Blind two-thermocouple sensor characterisation

Thermocouples are one of the most popular devices for temperature measurement in many mechatronic implementations. However, large wire diameters are required to withstand harsh environments and consequently the sensor bandwidth is reduced. This paper describes a novel algorithmic compensation technique based on blind deconvolution to address this loss of high frequency signal components using t...

متن کامل

Performance and Durability of Thin Film Thermocouple Array on a Porous Electrode

Management of solid oxide fuel cell (SOFC) thermal gradients is vital to limit thermal expansion mismatch and thermal stress. However, owing to harsh operation conditions of SOFCs and limited available space in stack configuration, the number of techniques available to obtain temperature distribution from the cell surface is limited. The authors previously developed and studied a thermocouple a...

متن کامل

Reliability and validity of electrothermometers and associated thermocouples.

OBJECTIVE Examine thermocouple model uncertainty (reliability+validity). DESIGN First, a 3x3 repeated measures design with independent variables electrothermometers and thermocouple model. Second, a 1x3 repeated measures design with independent variable subprobe. INTERVENTION Three electrothermometers, 3 thermocouple models, a multi-sensor probe and a mercury thermometer measured a stable w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005