Inaccuracy of wrist-cuff oscillometric blood pressure devices: an arm position artefact?

نویسندگان

  • Adnan Mourad
  • Alastair Gillies
  • Shane Carney
چکیده

BACKGROUND Despite the increasing popularity of wrist-cuff blood pressure (BP) devices, their accuracy has not been established and international guidelines do not support their use. Because arm position influences BP measurement, it is possible that conflicting reports on wrist-cuff device accuracy reflects diverse arm positions. METHOD This study compared BP measured by two oscillometric devices, the upper arm-cuff OMRON HEM 705 CP and the OMRON R6 oscillometric wrist-cuff device. In the former BP was measured with the arm in two supported positions, dependent on a table (manufacturer's instructions) and horizontal (mid sternum), while the latter followed the manufacturer's instructions. RESULTS In contrast to the dependent arm where BP was significantly higher (P<0.05), the horizontal arm position with the arm-cuff produced a mean systolic and diastolic BP comparable to the wrist-cuff device where the wrist was at heart level being respectively, 137+/-29/80+/-16 and 134+/-27/77+/-16 mmHg. A close relationship over a wide BP range was also confirmed by least squares, least product linear regression and Bland-Altman analysis. CONCLUSION This study supports the use of wrist-cuff monitors for self/home use and underlines the need for a more precise definition for arm position when using all BP devices -- mercury and oscillometric.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparison of noninvasive blood pressure measurement on the wrist with invasive arterial blood pressure monitoring in patients undergoing bariatric surgery.

BACKGROUND In morbidly obese patients, oscillometric blood pressure measurements with an upper-arm cuff are often difficult to perform. The alternative method, invasive blood pressure monitoring, can be difficult to place and is associated with risks. A wrist-mounted blood pressure-monitoring device, the Vasotrac, provides accurate blood pressure measurements in lean patients. Even in the obese...

متن کامل

Discordant prevalence of hypertension using two different automated blood pressure measurement devices: a population-based study in Dar es Salaam (Tanzania).

OBJECTIVE The estimation of blood pressure is dependent on the accuracy of the measurement devices. We compared blood pressure readings obtained with an automated oscillometric arm-cuff device and with an automated oscillometric wrist-cuff device and then assessed the prevalence of defined blood pressure categories. METHODS Within a population-based survey in Dar es Salaam (Tanzania), we sele...

متن کامل

Oscillometric pressure pulse waveforms: their current and prospective applications in biomedical instrumentation

The objective of this paper is to describe current uses of oscillometric pressure pulse waveforms and to introduce several prospective applications of the waveforms. A specialized system (Carditor) for acquisition, processing and display of waveforms is described. Carditor was used to acquire a database of oscillometric blood pressure waveforms from a wrist cuff. The following prospective metho...

متن کامل

Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure.

OBJECT Self-measurement of blood pressure (BP) might offer some advantages in diagnosis and therapeutic evaluation and in patient management of hypertension. Recently, wrist-cuff devices for self-measurement of BP have gained more than one-third of the world market share. In the present study, we validated wrist-cuff devices and compared the results between wrist- and arm-cuff devices. The fact...

متن کامل

Blood pressure measurement: retrospective and prospective views.

Measurement of the arterial blood pressure (BP) is a time-honored, vital piece of medical information whose accuracy is seldom questioned. This review identifies the unappreciated weakness of the early validation data that compared the cuff to intra-arterial BP's. Unfortunately, the inaccuracy of the auscultatory systolic (SBP) and diastolic (DBP) measurements are necessarily transmitted to the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood pressure monitoring

دوره 10 2  شماره 

صفحات  -

تاریخ انتشار 2005