A portable forced oscillation device for respiratory home monitoring.

نویسندگان

  • J Rigau
  • R Farré
  • J Roca
  • S Marco
  • A Herms
  • D Navajas
چکیده

The increase in the prevalence of chronic respiratory diseases has resulted in a rise in health services provided at home. The forced oscillation technique (FOT) proves to be a useful tool when it is desired to assess lung function noninvasively, and particularly for patients in whom spirometry cannot be applied. As no portable FOT device is currently available, the aim of this study was to design and test a portable FOT system for ambulatory and home care applications. The system devised is based on a microprocessor, which allows online computation of respiratory resistance (Rrs) and reactance (Xrs) and reliability indices. The portable device was compared with a conventional FOT system by using signals from 14 patients with chronic respiratory disease. This device has the same computation capabilities and flexibility as conventional FOT systems and meets the requirements for home application. Rrs (14.2 +/- 6.0 cmH2O x s x L(-1), mean +/- SD) and Xrs (-5.3 +/- 2.7 cmH2O x s x L(-1)) measured at 5 Hz by the portable system virtually coincided with those computed with the reference conventional FOT system: mean differences +/-SD were 0.074 +/- 0.025 and 0.005 +/- 0.009 cmH2O x s x L(-1), respectively. This portable forced oscillation technique device could be a useful tool for monitoring respiratory mechanics in ambulatory and home care applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Unsupervised self-testing of airway obstruction by forced oscillation at the patient's home.

As active patient cooperation is not required, the forced oscillation technique (FOT) could be suitable for measuring airway obstruction in routine home applications. Nevertheless, FOT has never been used at the patient's home to date. The aim of this study was to assess the feasibility of FOT and the reproducibility of measured respiratory resistance (Rrs) in routine patient self-testing at ho...

متن کامل

Diagnosis of sleep apnea by automatic analysis of nasal pressure and forced oscillation impedance.

Detecting and differentiating central and obstructive respiratory events is an important aspect of the diagnosis of sleep-related breathing disorders with respect to the choice of an appropriate treatment. The purpose of this study was to evaluate the performance of a new algorithm for automated detection and classification of apneas and hypopneas, compared with visual analysis of standard poly...

متن کامل

Non-ionizing electromagnetic waves measurement and monitoring Systems

In this paper, portable and online monitoring systems for non-ionizing EMF measurement, as well as some measurement results in Tehran are discussed. First of all, standards and recommendations related to EMF monitoring, measurement and exposure such as ISIRI No.8567, ICNIRP guideline and ITU-K.83 are reviewed. Then, technical facts and operation of portable device and monitoring station are int...

متن کامل

A simplified method for monitoring respiratory impedance during continuous positive airway pressure.

The forced oscillation technique is useful in detecting changes in upper airway obstruction in patients with sleep apnoea undergoing continuous positive airway pressure (CPAP) ventilation. The aim of this study was to implement and evaluate a method for estimating respiratory impedance (Zrs) from the pressure and flow recorded at the inlet of the CPAP tubing. The method is based on correcting i...

متن کامل

A comparison of a new transtelephonic portable spirometer with a laboratory spirometer.

The Spirophone is a new, portable transtelephonic spirometer which records the slow and the forced expiratory vital capacity tests. Data can be transmitted via the telephone to a remote receiving centre, where a volume-time curve and the flow-volume curve are displayed on screen in real time. The aim of this study was to compare the newly developed transtelephonic spirometer, with a laboratory ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 19 1  شماره 

صفحات  -

تاریخ انتشار 2002