Isolated Power Systems (IPS) and Wet Locations in

ثبت نشده
چکیده

The National Fire Protection Association (NFPA) Standard for Healthcare Facilities (NFPA 99) requires that wet location patient care areas be provided with “special protection against electric shock.” This paper will list the hazards associated with electric shock and the interruption of electrical power. An Isolated Power System (IPS) is one way of providing such protection, and has the inherent advantage of not requiring an interruption of the power supply should a phase-to-fault condition occur. This paper explains the design principles and requirements behind an IPS and a Ground Fault Circuit Interrupters (GFCI) and the components they use, and why an IPS is advantageous versus a GFCI at minimizing the hazard of electric shock. A brief discussion of regulatory requirements and inconsistencies therein, is also given with regard to the definition of “wet location”. Finally, an analysis of the cost implications of GFCI devices versus isolated power systems is given.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Techno-Economic Assessment of Different Inlet Air Cooling Systems in Warm Dry & Wet Climate Stations

Performance of a gas turbine mainly depends on the inlet air temperature. The power output of a gas turbine depends on the flow of mass through it. This is precisely the reason why on hot days, when air is less dense, power output falls. The objective here is to assess the advanced systems applied in reducing the gas turbine intake air temperature and examine the merits from integration of the ...

متن کامل

The Impact of Superconducting Fault Current Limiter Locations on Voltage Sag in Power Distribution System

In this paper, the impacts of installing superconducting fault current limiter (SFCL)in radial and loop power distribution system are evaluated to improve voltage sag in both cases of with and without distributed generations (DG). Among various SFCLs, the hybrid type with a superconducting element in parallel with a current limiting reactor (CLR) is selected. This is more effective than resisto...

متن کامل

Isolated power system in Russia: A chance for renewable energies?

The Russian power system is diversified regionally and consists of one Unified Power System (UPS) and multiple isolated power systems. In the Russian Federation the policy on the use of renewable energies has been one of the most debated topics in recent years. In 2010, the Russian Renewable Energy Program was launched which aims to generate 4.5% of the entire electricity demand from renewable ...

متن کامل

Distance-Aware Beamforming for Multiuser Secure Communication Systems

Typical cryptography schemes are not well suited for low complexity types of equipment, e.g., Internet of things (IoT) devices, as they may need high power or impose high computational complexity on the device. Physical (PHY) layer security techniques such as beamforming (in multiple antennas systems)  are possible alternatives to provide security for such applications. In this paper, we consid...

متن کامل

مقایسه تطابق لبه‌ای سیستم‌های سرامیکی مختلف دندانی در شرایط In-vitro

Background and Aims: Marginal gap measurement in all ceramic restorations they are of fundamental important for the successful used. As some studies led to contradiction results, yhe aim of this study is to compare marginal gap restorations between 4 kinds of ceramic restorations Inceram, IPS-e.max Press, Zirconia (CAD/CAM) and PFM. Materials and Methods: In this In-vitro experimental research...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007