Comparison of automatic boundary detection and manual tracing technique in echocardiographic determination of left atrial volume.
نویسندگان
چکیده
Previous reports have indicated that echocardiography with automatic boundary detection (ABD) is useful for the noninvasive estimation of left ventricular volume. However, few data exist regarding the measurement of left atrial (LA) volume, which also provides pivotal information in the clinical setting. Therefore, the feasibility of LA volume measurement by ABD in comparison with the manual tracing using modified Simpson's method (SM) was evaluated. Fifty-nine patients with coronary artery-disease with sinus rhythm were examined. Using ABD, a region of interest was set around the LA border and mitral annulus from an apical four-chamber view. The maximal and minimal LA volume (Vmax and Vmin) were measured from the volume waveform. Using the SM, the maximal and minimal LA volume were measured by the manual tracing on frozen frames at the apical four-chamber view. The ABD displayed a curve of LA volume change that consisted of passive emptying, diastasis, and active emptying phases during the left ventricular diastolic period. Under these conditions, the Vmax and Vmin were 43.7 +/- 11.2 ml and 21.1 +/- 7.6 ml, respectively, yielding the volume change of 22.6 +/- 6.0 ml. By the SM, Vmax and Vmin were 43.1 +/- 9.9 ml (r = 0.94, p < 0.0001, y(ABD) = 0.91x (SM) + 3.6) and 22.0 +/- 9.0 ml (r = 0.91, p < 0.0001, y = 0.94x + 0.7), respectively, and the volume change was 22.8 +/- 6.1 ml (r = 0.82, p < 0.0001, y = 0.84x + 3.8). These results indicate that the ABD from the apical four-chamber approach could provide an accurate estimation of LA volume change, suggesting the potential value of this method in assessing LA function, although some technical difficulties need to be further overcome.
منابع مشابه
Left atrial size and function: assessment using echocardiographic automatic boundary detection.
OBJECTIVE To evaluate the waveforms of left atrial area changes obtained by automated boundary detection with newly developed acoustic quantification technology. DESIGN All subjects had measurements of left atrial areas taken in the apical four chamber, parasternal long axis, and parasternal short axis views using both conventional echocardiographic methods and automatic boundary detection on...
متن کاملMeasurement of Left Ventricular Myocardium Wall Instantaneous Motions with Echocardiographic Sequence Images
Background & Aims: One of the important aims of quantitative cardiac image processing is the clarification of myocardial motions in order to derive biomechanical behavior of the heart in the disease condition. In this study we presented a computerized analysis method for detecting the instantaneous myocardial changes by using 2D echocardiography images. Methods: The analysis was performed on th...
متن کاملA Semi-Automated Algorithm for Segmentation of the Left Atrial Appendage Landing Zone: Application in Left Atrial Appendage Occlusion Procedures
Background: Mechanical occlusion of the Left atrial appendage (LAA) using a purpose-built device has emerged as an effective prophylactic treatment in patients with atrial fibrillation at risk of stroke and a contraindication for anticoagulation. A crucial step in procedural planning is the choice of the device size. This is currently based on the manual analysis of the “Device Landing Zone” fr...
متن کاملSegmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network
Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...
متن کاملSegmentation of the Left Atrial Appendage in the Echocardiographic Images of the Heart Using a Deep Neural Network
Introduction: Cardiovascular diseases are one of the leading causes of mortality in today’s industrial world. Occlusion of left atrial appendage (LAA) using the manufactured devices is a growing trend. The objective of this study was to develop a computer-aided diagnosis system for the identification of LAA in echocardiographic images. Method: The data used in this descriptive analytical study ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Japanese circulation journal
دوره 62 10 شماره
صفحات -
تاریخ انتشار 1998