A constant-voltage and constant-current stimulus isolation unit.

نویسندگان

  • W Kadziela
  • R Tomaszewski
چکیده

When action potentials from a stimulated biological preparation are recorded i t is essential to isolate the stimulus resistively and capacitively from the ground in order to minimize stimulation artifacts. Such isolation can be achieved by using a transformer of special low-capacitance construction in the output of a stimulus generator (Donaldson 1958). The most widely used arrangement for the isolation, mentioned previously , is the Schmitt-type isolation unit (Schmitt 1948). It consists of a driven radio-frequency oscillator with its output rf link coupled to the preparation. The most recent isolation units are based on the light transmission of electrical stimulus from the generator to the preparation (Dawson et al. 1960, Ross and Bassett 1967). By using the stimulus isolation unit in the output of a stimulus generator, the stimulating current flows entirely between stimulating electrodes, whether the preparation is grounded or not. When, however, electrodes made of thin wire (usually of 0.1 or 0.2 mm in diameter) are used, in this case for intracerebral stimulation of laboratory animals, the stimulus yields to appreciable distortion. When the constant-voltage type stimulus isolation unit (device with low output impedance) is used a current pulse yields to distortion. It is caused by the electrochemical polarization of the elect?odes used for stimulation (Weinman and Mahler 1964, Greatbatch 1967). The small contact areas of the electrodes with the preparation are the cause of high current densities at the metal-preparation interface, resulting in electric polarization with the electrode behaving as a capacitance. The typical distortion of a rectangular current pulse is shown in Fig. l b. This distortion makes the measurement of the stimulating current difficult. Since it is generally accepted that

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An optically coupled power stimulus isolation unit with high voltage and fast rise time output.

Recent technological developments have created new devices that could improve and simplify the construction of stimulus isolators. HEXFET transistors can switch large currents and hundreds of volts in nanoseconds. The newer opto-isolators can give a pulse rise time of a few nanoseconds, with output compatible with MOSFET devices, in which delays are reduced to nanoseconds. Integrated DC/DC conv...

متن کامل

Advanced LIVA/TIVA Techniques

LIVA (Light Induced Voltage Alterations) and TIVA (Thermally Induced Voltage Alterations) have demonstrated significant capability for fault isolation. A difficulty with both techniques is their use of a constant current source, whereas integrated circuits operate with a constant voltage source. A new technique that utilizes the constant current sensing of LIVA/TIVA, while allowing for use of c...

متن کامل

Comparison of the effect of quasitrapezoidal and rectangular pulses on bio- electrical activity, calcium spike properties and afterhyperpolarization potentials of Fl cells of Helix aspersa using intracellular recording

  While the effect of changes of stimulus waveform (quasitrapezoidal and rectangular current pulses) on nerve activation is clear, but there is no evidence on the effect of quasitrapezoidal pulses on ionic currents of cellular membrane. In the present study, the effect of depolarizing quasi-trapezoidal current pulses, in comparison with that of depolarizing rectangular current pulses, on firing...

متن کامل

Lead-Lag Controllers Coefficients Tuning to Control Fuel Cell Based on PSO Algorithm

One of the most important Fuel cells (FCs) is Proton Exchange Membrane Fuel Cells (PEMFCs). The outputvoltage of this FC depends on current loads. This paper tries to introduce, implement and control the voltage ofPEMFC, during load variations. The output voltage of fuel cell should be constant during load variation. Toachieve this goal, a controller should be designed. Here, the Lead-Lag contr...

متن کامل

A Simulation Analysis of Grid Synchronized H- Bridge Multilevel Inverter with PV Module – An Open Loop Study

ABSTRACT: In the power generation sector, Natural Resources like Solar, Wind, Tidal, Geothermal, Hydro etc have always played a very important role. Out of these solar PV (photo voltaic) is most popular due to its significant advantages. However the solar radiation never remains constant. It keeps on varying throughout the day. In this paper, single 60 W solar PV panel along with boost converte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta neurobiologiae experimentalis

دوره 30 2  شماره 

صفحات  -

تاریخ انتشار 1970