Aortic valve replacement with a rapid deployment Edwards Intuity bioprosthesis using a completely video-guided approach.

نویسندگان

  • Tommaso Hinna Danesi
  • Giovanni Domenico Cresce
  • Alessandro Favaro
  • Massimo Bilotta
  • Loris Salvador
چکیده

We describe the case of a 54-year-old female with severe aortic stenosis and a background of severe comorbidities including prior radiotherapy for Hodgkin’s lymphoma, splenectomy, severe chronic obstructive pulmonary disease, scleroderma with laryngeal and esophageal involvement, and systemic and pulmonary hypertension. The patient underwent totally video-guided aortic valve replacement through a minimally invasive right anterior thoracotomy (Video 1).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Edwards Intuity Aortic Bioprosthesis in Patient with Bicuspid Aortic Valve

Bicuspid aortic valve (BAV) is generally considered to be a contraindication to sutureless aortic valve replacement (AVR). Implantation of the Edwards Intuity aortic bioprosthesis is an innovative approach associated with superior hemodynamic performance, significantly reduced myocardial ischaemia and cardiopulmonary bypass times and proves to be suitable for type 1 and 2 of bicuspid aortic val...

متن کامل

Minimally invasive rapid deployment Edwards Intuity aortic valve implantation.

The corresponding video is a rapid deployment aortic valve replacement (RDAVR) using the first generation of the Intuity RDAVR system (Edwards Lifesciences; Irvine, CA, USA) via a minimally invasive approach (Video 1). The patient is a 73-year-old female with symptomatic, severe aortic stenosis. She has NYHA III symptoms with a mean aortic valve gradient of 50 mmHg. The patient has a mildly dil...

متن کامل

'Fast-implantable' aortic valve implantation and concomitant mitral procedures.

Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mi...

متن کامل

Does adoption of new technologies require high operative volume? Our results with sutureless aortic bioprostheses.

Aims/Objectives The aim of this study is to review our results with the Edwards Intuity Elite sutureless bioprosthetic aortic valve. Methods The perioperative data of patients who underwent aortic valve replacement during the last year by sutureless bioprotheses (Edwards Intuity Elite, n = 7) were reviewed retrospectively and compared to those who received a conventional bioprostheses (Edwards ...

متن کامل

Rapid Deployment Aortic Valves Deliver Superior Hemodynamic Performance In Vitro

OBJECTIVE Clinical studies have demonstrated excellent hemodynamic performance of rapid deployment aortic valves; however, few studies have directly compared the performance of these valves with conventional bioprosthetic valves. Thus, the hemodynamic function of the EDWARDS INTUITY valve (rapid deployment valve) was compared with the Edwards Magna Ease valve in vitro (Edwards Lifesciences Corp...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Annals of cardiothoracic surgery

دوره 4 2  شماره 

صفحات  -

تاریخ انتشار 2015