Targeted total marrow irradiation using three-dimensional image-guided tomographic intensity-modulated radiation therapy: an alternative to standard total body irradiation.

نویسندگان

  • Jeffrey Y C Wong
  • An Liu
  • Timothy Schultheiss
  • Leslie Popplewell
  • Anthony Stein
  • Joseph Rosenthal
  • Mark Essensten
  • Stephen Forman
  • George Somlo
چکیده

Total body irradiation (TBI) is an important part of bone marrow transplantation conditioning regimens. In TBI, dose escalation is difficult, because of associated normal organ toxicities. A method to deliver a more targeted dose of TBI preferentially to sites of greatest tumor burden is needed to reduce the dose to normal organs, reduce toxicities, and permit dose escalation. The purpose of this study was to evaluate, through a dosimetric analysis, the potential advantages and feasibility of selectively delivering targeted myeloablative doses of radiation to bone and marrow using a recently developed image-guided tomographic intensity-modulated radiation therapy delivery system (helical tomotherapy). Whole-body computed tomography datasets from 3 patients, age 5, 20, and 53 years, were used for treatment planning studies to evaluate 2 targeted TBI strategies: total marrow irradiation (TMI), in which the target region was defined as the skeletal bone, and total marrow and lymphoid irradiation (TMLI), in which the target regions were defined as bone, major lymph node chains, liver, spleen, and sanctuary sites, such as brain. Organ doses and dose distributions were compared with those in conventional TBI. A 1.7- to 7.5-fold reduction in median organ doses was observed with TMI and TMLI compared with conventional TBI. With this more targeted approach, a dose-volume histogram analysis predicted the potential to escalate the dose to bone (and containing marrow) up to 20 Gy, while maintaining doses to normal organs at lower levels than in conventional TBI to 12 Gy. Results were similar for the adult and pediatric patients, indicating that this form of targeted TBI will be applicable to most patients regardless of frame size. TMI to 10 Gy was delivered as part of a tandem transplant regimen to the 53-year-old patient with multiple myeloma. Clinical results confirmed the treatment planning predictions. After TMI, the patient experienced the expected blood count nadir, followed by successful engraftment. Grade 2 nausea and grade 1 emesis occurred only briefly on day 2 of TMI. Skin erythema, oral mucositis, esophagitis, and enteritis were not observed. This report demonstrates the feasibility and potential dosimetric advantages of selectively delivering myeloablative doses of radiation to bone and marrow using an image-guided tomographic intensity-modulated radiation therapy delivery system. Organ doses are substantially lower than those associated with standard TBI and predict the potential to significantly reduce associated toxicities and allow for dose escalation. The results also suggest that this form of targeted TBI may have potential advantages over other forms of targeted TBI, such as radioimmunotherapy or bone-seeking radionuclide therapy. Ongoing clinical trials will define the maximum TMI and TMLI doses achievable and define the potential advantages and limitations of this new approach for patients undergoing hematopoietic stem cell transplantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Feasibility study for linac-based intensity modulated total marrow irradiation.

Total body irradiation (TBI) is used as a preconditioning regimen prior to bone marrow transplant for treatment of hematologic malignancies. During TBI, large volumes of normal tissue are irradiated, and this can lead to toxicities, most significantly in the lungs. Intensity modulated total marrow irradiation (IMTMI) may be able to reduce these toxicities by directly targeting the bone marrow w...

متن کامل

The evaluation of lung doses for radiation pneumonia risk in stereotactic body radiotherapy: A comparison of intensity modulated radiotherapy, intensity modulated arc therapy, cyberknife and helical tomotherapy

Background: Radiation Pneumonia (RP) is one of the most extensive side effects in Stereotactic Body Radiotherapy (SBRT) of lung cancer. SBRT are performed by means of Intensity Modulated Radiotherapy (IMRT), Intensity Modulated Arc Therapy (IMAT), CyberKnife (CK) or Helical Tomotherapy (HT) treatment methods. In this study, we performed a plan study to determine the plan parameter such as the M...

متن کامل

Feasibility of intrafraction whole-body motion tracking for total marrow irradiation.

With image-guided tomotherapy, highly targeted total marrow irradiation (TMI) has become a feasible alternative to conventional total body irradiation. The uncertainties in patient localization and intrafraction motion of the whole body during hour-long TMI treatment may pose a risk to the safety and accuracy of targeted radiation treatment. The feasibility of near-infrared markers and optical ...

متن کامل

A set cover approach to fast beam orientation optimization in intensity modulated radiation therapy for total marrow irradiation.

The beam orientation optimization (BOO) problem in intensity modulated radiation therapy (IMRT) treatment planning is a nonlinear problem, and existing methods to obtain solutions to the BOO problem are time consuming due to the complex nature of the objective function and size of the solution space. These issues become even more difficult in total marrow irradiation (TMI), where many more beam...

متن کامل

Dosimetric comparison of 3-dimensional conformal and intensity-modulated radiotherapy techniques for whole breast irradiation in the prone and supine positions

Background: The aim of this study was to compare the differences of the dosimetric parameters between three-dimensional conformal radiotherapy (3D-CRT) and simultaneous-integrated boost intensity-modulated radiotherapy (SIB-IMRT) techniques in the prone and supine positions for breast irradiation. Materials and Methods: Ten patients underwent a computed tomography simulation in both the prone a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biology of blood and marrow transplantation : journal of the American Society for Blood and Marrow Transplantation

دوره 12 3  شماره 

صفحات  -

تاریخ انتشار 2006